Highlights at a glance:
|
|
| Mainboards | ||
| Manufacturer | ASUS |
Supermicro |
| Mainboards | P13R-I | X13SCL-IF |
| Chipset | Intel C262 | Intel C262 |
| Socket | Intel LGA 1700 - Server | Intel LGA 1700 - Server |
| Processor | Xeon E-2400 (Raptor Lake-E) | Xeon E-2400 (Raptor Lake-E) |
| Main Memory | 2 DIMMs
64 GiB DDR5 4800/4400 ECC Unbuffered |
2 DIMMs
64 GiB DDR5 4800 ECC Unbuffered |
| LAN Onboard | 2 x 1 GBit/s LAN (RJ-45) |
2 x 1 GBit/s LAN (RJ-45) |
| LAN chipset | Intel I210-AT2 | Intel i210 |
| LAN Onboard (dedicated IPMI) | 1 | 1 |
| Onboard graphic | ASPEED AST2600 BMC | 1x VGA ASPEED AST2600 BMC |
| Additional card (optional) | PNY NVIDIA RTX A1000 (8GB) | PNY NVIDIA RTX A1000 (8GB) |
| Onboard Input/Output | USB (no PS2 ports!) |
USB (no PS2 ports!) 1x TPM Header |
| USB ports | 4x USB (rear) | 4x USB (rear) 2x USB 2.0, 2x USB 3.2 0x USB on board (type A) |
| Extension-slots for additional cards | ||
| PCI slots (mainboard) | 1x PCIe 5.0 x16 |
1x PCIe 5.0 x16 |
| Available slots in the chassis | 1x Full profile/Half Length | 1x Full profile/Half Length |
| Possible Riser cards | 1x PCI-E (x16) riser card |
1x PCI-E (x16) riser card |
| Onboard ports | ||
| SATA-3 (6 Gb/s) | 6x SATA-3 (6 Gbit/s) Intel C262 RAID 0, 1, 10, 5 |
6x SATA-3 (6 Gbit/s) Intel C262 RAID 0, 1, 10, 5 |
| M.2 | 1 x M.2 PCIe 3.0 x4 | 1 x M.2 PCIe 3.0 x4 |
| M.2 form factor | 2280 | 2280 |
| Drives / storage capacity | |
| Drive slots (total) | 2x 2.5" (Not hot-swap)
|
| Backplane | without Backplane |
| Max. capacity HDD (SATA) | 15.36 TB |
| Max. capacity SSD (SATA) | 15.36 TB |
| Server management | |
| Remote management | Integrated IPMI (dedicated NIC) |
| Chassis | |
| Unit | 1U |
| Dimensions | 43 mm (H), 437 mm (W), 249 mm (D), |
| drives (in scope of delivery) | not contained, optional available |
| Drives (optional) | External USB-drives |
| Fan (center) | 2x 40x40x28mm non-hot-swap (13000rpm, 52.5dBA) |
| Power supply | |
| Power supply unit | 1HE Supermicro Chassis CSE-504-203B |
| energy efficiency | 90.51% |
| PMBus support | No |
| Rack Assembly | |
| Assembly rails | no mounting rails available |
| environment-requirements | |
| Recommended ambient temperature | 20 - 22 degree |
| Recommended humidity | max. 40% |
| Recommended deployment location | To ensure the optimal cooling of the system, we recommend running the server in an air conditioned server room and as part of a rack installation. |