Dream server incl.
Windows Server 2022 Essentials
Rack system, tower or microserver? You decide!
Highlights at a glance:
|
|
Mainboards | |
Manufacturer | Supermicro |
Mainboards | H12DSi-NT6 |
Chipset | AMD System on Chip |
Socket | AMD SP3 |
Processor | AMD EPYC 7002/7003 (Rome/Milan) |
Main Memory | 16 DIMMs
2 TB DDR4 3200 RDIMM/SDRAM |
LAN Onboard | 2x 10 Gbit/s LAN (RJ-45) |
LAN chipset | Broadcom BCM57416 |
Onboard graphic | 1x VGA Aspeed AST2500 BMC |
Additional card (optional) | PNY NVIDIA Quadro T1000 (4GB) |
Onboard Input/Output | USB (no PS2 ports!) 1x TPM 2.0 header 1x COM port (rear) |
USB ports | 4x USB (rear) (2x USB 2.0, 2x USB 3.0) 0x USB on board (type A) |
Extension-slots for additional cards | |
PCI slots (mainboard) | 3x PCIe 4.0 x16 3x PCIe 4.0 x8 |
Available slots in the chassis | 6x Low profile/Half Length/Full Length |
Onboard ports | |
SATA-3 (6 Gb/s) | 10x SATA-3 (6 Gbit/s) AMD SoC Software-Raid |
M.2 | 1 x M.2 PCIe 3.0 x4 |
M.2 form factor | 2280, 22110 |
NVMe | 4x NVMe onboard |
Drives / storage capacity | |
Drive slots (total) | 8x 3.5" / 2.5" (Hot-swap)
2x 2.5" (Internal, non-hot-swap) |
Backplane | SATA / SAS-3 (12 Gb/s) |
Max. capacity HDD (SAS) | 176 TB |
Max. capacity HDD (SATA) | 176 TB |
Max. capacity SSD (SATA) | 61.44 TB |
Max. capacity SSD (SATA) | 61.44 TB |
Server management | |
Management software | Supermicro SuperDoctor 5 |
Remote management | Integrated IPMI (dedicated NIC) |
Features | Managementsoftware IPMI View IPMI with KVM Over LAN Serial Over LAN (SOL) Virtual Media Over LAN (Virtual USB Floppy/CD and Drive Redirection) LAN Alert-SNMP Trap Event Log OS Independent Hardware Health Monitor Remote Power Control Support RMCP & RMCP + Protocols Fan Speed Control Temperature Monitoring and Recovery Email Alerting |
Chassis | |
Unit | 2U |
Dimensions | 89 mm (H), 437 mm (W), 647 mm (D), |
drives (in scope of delivery) | not contained, optional available |
Drives (optional) | 1x Slim CD/DVD/DVD-R External USB-drives |
Fan (center) | 3x 80x80x38mm Hot-swap (7000rpm, 53.5dBA) |
Silent blowerkit option | no |
Power supply | |
Power supply unit | 1x 600 Watt Netzteil (80plus Platinum) |
energy efficiency | 92.48% |
PMBus support | Yes, Ver.1.2 |
Rack Assembly | |
Assembly rails | contained in the scope of supply |
rail length | 675-880 mm |
Total length server front to end of assembly rail | 820 mm |
Max. extraction length | 670 mm |
Recommended maneuvering space | 75 mm (minimum) |
environment-requirements | |
Recommended ambient temperature | 20 - 22 degree |
Recommended humidity | max. 40% |
Recommended deployment location | To ensure the optimal cooling of the system, we recommend running the server in an air conditioned server room and as part of a rack installation. The server is not ideal for use in an office environment due to its high noise levels. |