Adaptec Series 6 RAID Controller
Aus Wiki Thomas-Krenn.AG
In diesem Artikel finden Sie Informationen zu Adaptec Series 6 (Adaptec Unified Serial SAS/SATA 6 Gb) RAID Controllern.
Inhaltsverzeichnis |
Allgemeine Informationen
- RAID Controller Serie: Adaptec Series 6 (Adaptec Unified Serial SAS/SATA 6 Gb)
- Schnittstelle: 6Gb/s SAS (SAS-2) / PCIe 2.0
- Bauhöhe: Low Profile (Slot-Blech für Low Profile und Full Profile enthalten)
- Weitere Informationen:
- Vier SAS 2.0 RAID-Controller mit 6 Gb/s im Test: Adaptec RAID 6805 (tomshardware.de, 12.09.2011)
- Linux Drivers For Series 6 Controllers (adaptec.com/weblog, 18.11.2011), aktualisierter aacraid Treiber im Linux Kernel 2.6.39
Modelle
| RAID Controller | Ports intern |
Ports extern |
PCIe Lanes | Cache | Cache-Schutz | RAID-Level | Max. Anzahl HDDs bei Verw. von SAS Expandern |
Anmerkungen |
|---|---|---|---|---|---|---|---|---|
| Adaptec ASR6405 | 4 | - | 8 | 512MB | Optional (ZMCP) | 0, 1, 10, 1E, 5, 50[1], 6, 60[1], JBOD, Single Disk | 256 | |
| Adaptec ASR6405E | 4 | - | 1 | 128MB | Nein | 0, 1, 10, 1E, JBOD | 4 | |
| Adaptec ASR6405T | 4 | - | 8 | 512MB | Optional (ZMCP) | 0, 1, 10, 1E, 5, 50[1], 6, 60[1], JBOD, Single Disk | 256 | |
| Adaptec ASR6445 | 4 | 4 | 8 | 512MB | Optional (ZMCP) | 0, 1, 10, 1E, 5, 50, 6, 60, JBOD, Single Disk | 256 | |
| Adaptec ASR6805 | 8 | - | 8 | 512MB | Optional (ZMCP) | 0, 1, 10, 1E, 5, 50, 6, 60, JBOD, Single Disk | 256 | |
| Adaptec ASR6805E | 8 | - | 4 | 128MB | Nein | 0, 1, 10, 1E, JBOD | 4 | |
| Adaptec ASR6805Q | 8 | - | 8 | 512MB | ZMCP | 0, 1, 10, 1E, 5, 50, 6, 60, JBOD, Single Disk | 256 | maxCache 2.0 |
| Adaptec ASR6805T | 8 | - | 8 | 512MB | Optional (ZMCP) | 0, 1, 10, 1E, 5, 50, 6, 60, JBOD, Single Disk | 256 | |
| Adaptec ASR6805TQ | 8 | - | 8 | 512MB | ZMCP | 0, 1, 10, 1E, 5, 50, 6, 60, JBOD, Single Disk | 256 | maxCache 2.0 |
Versionsinformationen
Build 18668 (09 Dec 2011)
- Release Notes Build 18668, Auszug aus Enhancements and Bug Fixes:
- New Series 6 controllers released (6405T, 6805T, 6805Q, 6805TQ).
- Support for maxCache 2.0 read & write back caching (Q models).
- Big Block Cache Bypass mode for enhanced performance in data center environments.
- VMWare 5.0 email notification & ARCCONF management support.
- Several enhancements made to maxCache for improved functionality.
- Adaptec Storage Manager v7.30.18837 Readme
Build 18301
- (Initiale Firmware)
Anmerkungen
- ↑ 1,0 1,1 1,2 1,3 erfordert zusätzlichen SAS Expander, z.B. durch Verwendung einer SAS Expander Backplane