Dream server incl.
Windows Server 2022 Essentials
Rack system, tower or microserver? You decide!
Highlights at a glance:
|
|
Mainboards | |||
Manufacturer | Supermicro |
Supermicro | Supermicro |
Mainboards | X12SPL-F | X12SPL-LN4F | X12SPi-TF |
Chipset | Intel C621A | Intel C621A | Intel C621A |
Socket | Intel LGA 4189 | Intel LGA 4189 | Intel LGA 4189 |
Processor | Intel Xeon Scalable 3rd Gen | Intel Xeon Scalable 3rd Gen | Intel Xeon Scalable 3rd Gen |
Main Memory | 8 DIMMs
1 TB DDR4 3200 RDIMM |
8 DIMMs
1 TB DDR4 3200 RDIMM |
8 DIMMs
1 TB DDR4 3200 RDIMM |
LAN Onboard | 2 x 1 GBit/s LAN (RJ-45) |
4 x 1 GBit/s LAN (RJ-45) |
2x 10 Gbit/s LAN (RJ-45) |
LAN chipset | Intel i210 | Intel i210 | Intel X550 |
LAN Onboard (dedicated IPMI) | 1x RJ45 Dedicated IPMI LAN port | 1x RJ45 Dedicated IPMI LAN port | 1x RJ45 Dedicated IPMI LAN port |
Onboard graphic | 1x VGA ASPEED AST2600 BMC | 1x VGA ASPEED AST2600 BMC | 1x VGA ASPEED AST2600 BMC |
Onboard Input/Output | USB (no PS2 ports!) 1x TPM Header 1x COM Port (header) |
USB (no PS2 ports!) 1x TPM Header 1x COM Port (header) |
USB (no PS2 ports!) 1x TPM Header 1x COM port (rear) |
USB ports | 4x USB (rear) 1x USB on board (type A) | 4x USB (rear) 1x USB on board (type A) | 4x USB (rear) 1x USB on board (type A) |
Extension-slots for additional cards | |||
PCI slots (mainboard) | 3x PCIe 3.0 x8 2x PCIe 4.0 x16 2x PCIe 4.0 x8 |
3x PCIe 3.0 x8 2x PCIe 4.0 x16 2x PCIe 4.0 x8 |
3x PCIe 4.0 x16 2x PCIe 4.0 x8 |
Available slots in the chassis | 1x Full profile/Half Length | 1x Full profile/Half Length | 1x Full profile/Half Length |
Possible Riser cards | 1x PCI-E (x16) riser card |
1x PCI-E (x16) riser card |
1x PCI-E (x16) riser card |
Onboard ports | |||
SATA-3 (6 Gb/s) | 12x SATA-3 (6 Gbit/s) Intel C621A RAID 0, 1, 10, 5, Software-Raid |
12x SATA-3 (6 Gbit/s) Intel C621A RAID 0, 1, 10, 5, Software-Raid |
10x SATA-3 (6 Gbit/s) Intel C621A RAID 0, 1, 10, 5, Software-Raid |
Port distribution | 8x Intel PCH 0x Intel SCU 2x SuperDOM support |
8x Intel PCH 0x Intel SCU 2x SuperDOM support |
8x Intel PCH 0x Intel SCU 2x SuperDOM support |
M.2 | 1 x M.2 PCIe 3.0 x4, SATA | 1 x M.2 PCIe 3.0 x4 | 1 x M.2 PCIe 3.0 x4, SATA |
M.2 form factor | 2280, 22110 | 2280, 22110 | 2280, 22110 |
NVMe | 0x NVMe onboard | 0x NVMe onboard | 2x NVMe onboard |
Drives / storage capacity | |
Drive slots (total) | 4x 3.5" / 2.5" (Hot-swap)
|
Backplane | SATA / SAS-3 (12 Gb/s) |
Max. capacity HDD (SAS) | 88 TB |
Max. capacity HDD (SATA) | 88 TB |
Max. capacity SSD (SATA) | 30.72 TB |
Max. capacity SSD (SATA) | 30.72 TB |
Server management | |
Management software | Supermicro SuperDoctor 5 |
Remote management | Integrated IPMI (dedicated NIC) |
Features | Managementsoftware IPMI View IPMI with KVM Over LAN Serial Over LAN (SOL) Virtual Media Over LAN (Virtual USB Floppy/CD and Drive Redirection) LAN Alert-SNMP Trap Event Log OS Independent Hardware Health Monitor Remote Power Control Support RMCP & RMCP + Protocols Fan Speed Control Dedicated 3. network interface card |
IPMI-sensors | CPU-temperature (OK / warning) system-temperature (Celsius degree) Electronic voltage (volt) Cooler speed (RPM) Additional model-dependent sensors (www.thomas-krenn.com/ipmi-sensoren) |
Chassis | |
Unit | 1U |
Dimensions | 43 mm (H), 437 mm (W), 503 mm (D), |
drives (in scope of delivery) | not contained, optional available |
Drives (optional) | 1x Slim CD/DVD/DVD-R External USB-drives |
Fan (center) | 4x 40x40x28mm non-hot-swap (17500rpm, 57.5dBA) |
Silent blowerkit option | no |
Power supply | |
Power supply unit | 1x 350 Watt Netzteil (80plus Platinum) |
energy efficiency | 92.51% |
PMBus support | PSU single: no, redundant PSU: Yes, Ver.1.2 |
Rack Assembly | |
Assembly rails | contained in the scope of supply |
rail length | 660 - 845 mm |
Total length server front to end of assembly rail | 705 mm |
Max. extraction length | 710 mm |
Recommended maneuvering space | 75 mm (minimum) |
environment-requirements | |
Recommended ambient temperature | 20 - 22 degree |
Recommended humidity | max. 40% |
Recommended deployment location | To ensure the optimal cooling of the system, we recommend running the server in an air conditioned server room and as part of a rack installation. The server is not ideal for use in an office environment due to its high noise levels. |