MegaRAID 9540-2M2 Series RAID Controller
Zur Navigation springen
Zur Suche springen
In diesem Artikel finden Sie Informationen zum Broadcom 9540-2M2 M.2 RAID Controller. Der RAID Controller basiert so wie der MegaRAID 9540-8i auf dem Broadcom SAS3808 Chip - bietet aber durch seine beiden M.2 Slots die Möglichkeit eines Hardware-RAIDs ohne dabei HotSwap-Einschübe zu belegen.
Allgemeine Informationen
- Schnittstelle: TriMode SATA & NVMe / PCIe 4.0 x8
- Bauhöhe: Low Profile (Slot-Blech für Low Profile und Full Profile enthalten)
- M.2 Socket: 2x (supporting 22110, 2280, 2260, 2242 & 2230)
- RAID erstellen: siehe RAID erstellen mit StorCLI
Modelle
9540-2M2 | ||
---|---|---|
IC Family | SAS3808
I/O controller (IOC) | |
M.2 Ports | 2 | |
Cache | - | |
RAID-Level | 0, 1 | |
VMware IO HCL | ID 57656 | |
Windows Server Catalog | 9540-2M2 | |
IDs | VID | 1000 |
DID | 10e6 | |
SVID | 1000 | |
SSID | 40e0 |
Programmausgaben
lspci
# lspci -vvv -nn -s 51:00.0 RAID bus controller [0104]: Broadcom / LSI MegaRAID 12GSAS/PCIe Secure SAS38xx [1000:10e6] Subsystem: Broadcom / LSI MegaRAID 12GSAS/PCIe Secure SAS38xx [1000:40e0] Physical Slot: 85 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Latency: 0, Cache Line Size: 32 bytes Interrupt: pin A routed to IRQ 18 NUMA node: 0 Region 0: Memory at 20bfffe00000 (64-bit, prefetchable) [size=1M] Region 2: Memory at 20bfffd00000 (64-bit, prefetchable) [size=1M] Region 4: Memory at d0e00000 (32-bit, non-prefetchable) [size=1M] Region 5: I/O ports at a000 [size=256] Expansion ROM at d0d00000 [disabled] [size=1M] Capabilities: [40] Power Management version 3 Flags: PMEClk- DSI- D1+ D2+ AuxCurrent=0mA PME(D0-,D1-,D2-,D3hot-,D3cold-) Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME- Capabilities: [50] MSI: Enable- Count=1/1 Maskable+ 64bit+ Address: 0000000000000000 Data: 0000 Masking: 00000000 Pending: 00000000 Capabilities: [70] Express (v2) Endpoint, MSI 00 DevCap: MaxPayload 1024 bytes, PhantFunc 0, Latency L0s unlimited, L1 <64us ExtTag+ AttnBtn- AttnInd- PwrInd- RBE+ FLReset+ SlotPowerLimit 0.000W DevCtl: CorrErr- NonFatalErr- FatalErr+ UnsupReq- RlxdOrd+ ExtTag+ PhantFunc- AuxPwr- NoSnoop+ FLReset- MaxPayload 512 bytes, MaxReadReq 512 bytes DevSta: CorrErr+ NonFatalErr- FatalErr- UnsupReq+ AuxPwr- TransPend- LnkCap: Port #0, Speed 16GT/s, Width x8, ASPM L0s L1, Exit Latency L0s unlimited, L1 <64us ClockPM- Surprise- LLActRep- BwNot- ASPMOptComp+ LnkCtl: ASPM Disabled; RCB 64 bytes, Disabled- CommClk+ ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt- LnkSta: Speed 16GT/s (ok), Width x8 (ok) TrErr- Train- SlotClk+ DLActive- BWMgmt- ABWMgmt- DevCap2: Completion Timeout: Range ABCD, TimeoutDis+ NROPrPrP- LTR- 10BitTagComp+ 10BitTagReq- OBFF Not Supported, ExtFmt- EETLPPrefix- EmergencyPowerReduction Not Supported, EmergencyPowerReductionInit- FRS- TPHComp- ExtTPHComp- AtomicOpsCap: 32bit- 64bit- 128bitCAS- DevCtl2: Completion Timeout: 260ms to 900ms, TimeoutDis- LTR- OBFF Disabled, AtomicOpsCtl: ReqEn- LnkCap2: Supported Link Speeds: 2.5-16GT/s, Crosslink- Retimer+ 2Retimers+ DRS- LnkCtl2: Target Link Speed: 16GT/s, EnterCompliance- SpeedDis- Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB LnkSta2: Current De-emphasis Level: -3.5dB, EqualizationComplete+ EqualizationPhase1+ EqualizationPhase2+ EqualizationPhase3+ LinkEqualizationRequest- Retimer- 2Retimers- CrosslinkRes: Upstream Port Capabilities: [b0] MSI-X: Enable+ Count=128 Masked- Vector table: BAR=0 offset=00002000 PBA: BAR=0 offset=00003000 Capabilities: [100 v2] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq+ ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq+ ACSViol- UESvrt: DLP+ SDES+ TLP+ FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- AdvNonFatalErr+ CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- AdvNonFatalErr- AERCap: First Error Pointer: 00, ECRCGenCap+ ECRCGenEn- ECRCChkCap+ ECRCChkEn- MultHdrRecCap- MultHdrRecEn- TLPPfxPres- HdrLogCap- HeaderLog: 00000000 00000000 00000000 00000000 Capabilities: [148 v1] Power Budgeting <?> Capabilities: [158 v1] Alternative Routing-ID Interpretation (ARI) ARICap: MFVC- ACS-, Next Function: 0 ARICtl: MFVC- ACS-, Function Group: 0 Capabilities: [168 v1] Secondary PCI Express LnkCtl3: LnkEquIntrruptEn- PerformEqu- LaneErrStat: 0 Capabilities: [188 v1] Physical Layer 16.0 GT/s <?> Capabilities: [1b0 v1] Lane Margining at the Receiver <?> Capabilities: [248 v1] Vendor Specific Information: ID=0002 Rev=4 Len=100 <?> Capabilities: [348 v1] Vendor Specific Information: ID=0001 Rev=1 Len=038 <?> Capabilities: [380 v1] Data Link Feature <?> Kernel driver in use: megaraid_sas Kernel modules: megaraid_sas
storcli
Generating detailed summary of the adapter, it may take a while to complete. CLI Version = 007.2202.0000.0000 Mar 14, 2022 Operating system = Linux 5.15.0-56-generic Controller = 0 Status = Success Description = None Basics : ====== Controller = 0 Model = MegaRAID 9540-2M2 Serial Number = SPC4607833 Current Controller Date/Time = 02/24/2023, 13:22:23 Current System Date/time = 02/24/2023, 13:22:25 SAS Address = 500062b211c91900 PCI Address = 00:51:00:00 Mfg Date = 11/28/22 Rework Date = 00/00/00 Revision No = 06001 Version : ======= Firmware Package Build = 52.23.0-4636 Firmware Version = 5.230.01-3723 PSOC FW Version = 0x0006 PSOC Part Number = 14790 NVDATA Version = 5.2300.00-0613 CBB Version = 24.25.01.00 Bios Version = 7.23.00.0_0x07170100 HII Version = 07.23.03.00 HIIA Version = 07.23.03.00 Driver Name = megaraid_sas Driver Version = 07.717.02.00-rc1 Bus : === Vendor Id = 0x1000 Device Id = 0x10E6 SubVendor Id = 0x1000 SubDevice Id = 0x40E0 Host Interface = PCI-E Device Interface = SAS-12G Bus Number = 81 Device Number = 0 Function Number = 0 Domain ID = 0 Pending Images in Flash : ======================= Image name = No pending images Status : ====== Controller Status = Optimal Memory Correctable Errors = 0 Memory Uncorrectable Errors = 0 ECC Bucket Count = 0 Any Offline VD Cache Preserved = No BBU Status = NA PD Firmware Download in progress = No Support PD Firmware Download = Yes Lock Key Assigned = No Failed to get lock key on bootup = No Lock key has not been backed up = No Bios was not detected during boot = No Controller must be rebooted to complete security operation = No A rollback operation is in progress = No At least one PFK exists in NVRAM = No SSC Policy is WB = No Controller has booted into safe mode = No Controller shutdown required = No Controller has booted into certificate provision mode = No Current Personality = RAID-Mode Supported Adapter Operations : ============================ Rebuild Rate = Yes CC Rate = Yes BGI Rate = Yes Reconstruct Rate = Yes Patrol Read Rate = Yes Alarm Control = No Cluster Support = No BBU = NA Spanning = Yes Dedicated Hot Spare = Yes Revertible Hot Spares = Yes Foreign Config Import = Yes Self Diagnostic = Yes Allow Mixed Redundancy on Array = No Global Hot Spares = Yes Deny SCSI Passthrough = No Deny SMP Passthrough = No Deny STP Passthrough = No Support more than 8 Phys = Yes FW and Event Time in GMT = No Support Enhanced Foreign Import = Yes Support Enclosure Enumeration = Yes Support Allowed Operations = Yes Abort CC on Error = Yes Support Multipath = Yes Support Odd & Even Drive count in RAID1E = No Support Security = Yes Support Config Page Model = Yes Support the OCE without adding drives = Yes Support EKM = Yes Snapshot Enabled = No Support PFK = Yes Support PI = No Support Ld BBM Info = No Support Shield State = Yes Block SSD Write Disk Cache Change = No Support Suspend Resume BG ops = Yes Support Emergency Spares = Yes Support Set Link Speed = Yes Support Boot Time PFK Change = No Support JBOD = Yes Disable Online PFK Change = No Support Perf Tuning = Yes Support SSD PatrolRead = Yes Real Time Scheduler = Yes Support Reset Now = Yes Support Emulated Drives = Yes Headless Mode = Yes Dedicated HotSpares Limited = No Point In Time Progress = Yes Extended LD = No Support Uneven span = No Support Config Auto Balance = No Support Maintenance Mode = No Support Diagnostic results = Yes Support Ext Enclosure = Yes Support Sesmonitoring = Yes Support SecurityonJBOD = Yes Support ForceFlash = Yes Support DisableImmediateIO = Yes Support LargeIOSupport = No Support DrvActivityLEDSetting = Yes Support FlushWriteVerify = No Support CPLDUpdate = No Support ForceTo512e = Yes Support discardCacheDuringLDDelete = No Support JBOD Write cache = No Support Large QD Support = No Support Ctrl Info Extended = Yes Support IButton less = Yes Support AES Encryption Algorithm = No Support Encrypted MFC = Yes Support Snapdump = Yes Support Force Personality Change = No Support Dual Fw Image = No Support PSOC Update = Yes Support Secure Boot = Yes Support Debug Queue = No Support Least Latency Mode = No Support OnDemand Snapdump = Yes Support Clear Snapdump = Yes Support FW Triggered Snapdump = Yes Support PHY current speed = Yes Support Lane current speed = Yes Support NVMe Width = Yes Support Lane DeviceType = Yes Support Extended Drive performance Monitoring = No Support NVMe Repair = Yes Support Platform Security = No Support None Mode Params = Yes Support Extended Controller Property = Yes Support Smart Poll Interval for DirectAttached = Yes Support Write Journal Pinning = No Support SMP Passthru with Port Number = Yes Support SnapDump Preboot Trace Buffer Toggle = No Support Parity Read Cache Bypass = Yes Support NVMe Init Error Device ConnectorIndex = No Support VolatileKey = Yes Support PSOC Part Information = Yes Enterprise Key management : ========================= Capability = Supported Boot Agent = Not Available Configured = No Supported PD Operations : ======================= Force Online = Yes Force Offline = Yes Force Rebuild = Yes Deny Force Failed = No Deny Force Good/Bad = No Deny Missing Replace = No Deny Clear = No Deny Locate = No Support Power State = Yes Set Power State For Cfg = No Support T10 Power State = No Support Temperature = Yes NCQ = Yes Support Max Rate SATA = No Support Degraded Media = No Support Parallel FW Update = Yes Support Drive Crypto Erase = Yes Support SSD Wear Gauge = No Support Sanitize = No Support Extended Sanitize = Yes Supported VD Operations : ======================= Read Policy = No Write Policy = No IO Policy = No Access Policy = Yes Disk Cache Policy = Yes Reconstruction = Yes Deny Locate = No Deny CC = No Allow Ctrl Encryption = No Enable LDBBM = Yes Support FastPath = Yes Performance Metrics = Yes Power Savings = No Support Powersave Max With Cache = No Support Breakmirror = No Support SSC WriteBack = No Support SSC Association = No Support VD Hide = Yes Support VD Cachebypass = Yes Support VD discardCacheDuringLDDelete = No Support VD Scsi Unmap = Yes Advanced Software Option : ======================== ----------------------------------------- Adv S/W Opt Time Remaining Mode ----------------------------------------- MegaRAID FastPath Unlimited - MegaRAID SafeStore Unlimited - ----------------------------------------- Safe ID = XQUCARN3BUEP1VM7TW7HRRWVW45RH9N2DTXPLNIZ HwCfg : ===== ChipRevision = A0 BatteryFRU = N/A Front End Port Count = 0 Backend Port Count = 16 BBU = Absent Alarm = Absent Serial Debugger = Present NVRAM Size = 128KB Flash Size = 32MB On Board Memory Size = 0MB CacheVault Flash Size = NA TPM = Absent Upgrade Key = Absent On Board Expander = Absent Temperature Sensor for ROC = Present Temperature Sensor for Controller = Absent Upgradable CPLD = Absent Upgradable PSOC = Present Current Size of CacheCade (GB) = 0 Current Size of FW Cache (MB) = 0 ROC temperature(Degree Celsius) = 39 Policies : ======== Policies Table : ============== ------------------------------------------------ Policy Current Default ------------------------------------------------ Predictive Fail Poll Interval 300 sec Interrupt Throttle Active Count 16 Interrupt Throttle Completion 50 us Rebuild Rate 30 % 30% PR Rate 30 % 30% BGI Rate 30 % 30% Check Consistency Rate 30 % 30% Reconstruction Rate 30 % 30% Cache Flush Interval 4s ------------------------------------------------ Flush Time(Default) = 4s Drive Coercion Mode = none Auto Rebuild = On Battery Warning = Off ECC Bucket Size = 15 ECC Bucket Leak Rate (hrs) = 24 Restore Hot Spare on Insertion = Off Expose Enclosure Devices = On Maintain PD Fail History = On Reorder Host Requests = On Auto detect BackPlane = SGPIO/i2c SEP Load Balance Mode = Auto Security Key Assigned = Off Disable Online Controller Reset = Off Use drive activity for locate = Off Boot : ==== BIOS Enumerate VDs = 1 Stop BIOS on Error = Off Delay during POST = 0 Spin Down Mode = None Enable Ctrl-R = No Enable Web BIOS = No Enable PreBoot CLI = No Enable BIOS = Yes Max Drives to Spinup at One Time = 2 Maximum number of direct attached drives to spin up in 1 min = 0 Delay Among Spinup Groups (sec) = 2 Allow Boot with Preserved Cache = Off High Availability : ================= Topology Type = None Cluster Permitted = No Cluster Active = No Defaults : ======== Phy Polarity = 0 Phy PolaritySplit = 0 Strip Size = 64 KB Write Policy = WT Read Policy = No Read Ahead Cache When BBU Bad = Off Cached IO = Off VD PowerSave Policy = Controller Defined Default spin down time (mins) = 30 Coercion Mode = None ZCR Config = Unknown Max Chained Enclosures = 2 Direct PD Mapping = No Restore Hot Spare on Insertion = No Expose Enclosure Devices = Yes Maintain PD Fail History = Yes Zero Based Enclosure Enumeration = No Disable Puncturing = No EnableLDBBM = Yes DisableHII = No Un-Certified Hard Disk Drives = Allow SMART Mode = Mode 6 Enable LED Header = Yes LED Show Drive Activity = Yes Dirty LED Shows Drive Activity = No EnableCrashDump = No Disable Online Controller Reset = No Treat Single span R1E as R10 = No Power Saving option = Enabled TTY Log In Flash = Yes Auto Enhanced Import = Yes BreakMirror RAID Support = No Disable Join Mirror = Yes Enable Shield State = Yes Time taken to detect CME = 60 sec Capabilities : ============ Supported Drives = SAS, SATA, NVMe RAID Level Supported = RAID0, RAID1(2 or more drives), RAID00, RAID10(2 or more drives per span) Enable JBOD = Yes Mix in Enclosure = Allowed Mix of SAS/SATA of HDD type in VD = Allowed Mix of SAS/SATA of SSD type in VD = Not Allowed Mix of SSD/HDD in VD = Not Allowed SAS Disable = No Max Arms Per VD = 32 Max Spans Per VD = 8 Max Arrays = 32 Max VD per array = 16 Max Number of VDs = 32 Max Parallel Commands = 1517 Max SGE Count = 60 Max Data Transfer Size = 2048 sectors Max Strips PerIO = 20 Max Configurable CacheCade Size(GB) = 0 Max Transportable DGs = 0 Enable Snapdump = Yes Enable SCSI Unmap = Yes Read cache bypass enabled for Parity RAID LDs = Yes FDE Drive Mix Support = No Min Strip Size = 64 KB Max Strip Size = 64 KB Scheduled Tasks : =============== Consistency Check Reoccurrence = 168 hrs Next Consistency check launch = 02/25/2023, 03:00:00 Patrol Read Reoccurrence = 168 hrs Next Patrol Read launch = 02/25/2023, 03:00:00 Battery learn Reoccurrence = NA Next Battery Learn = NA OEMID = Broadcom Secure Boot : =========== Secure Boot Enabled = Yes Controller in Soft Secure Mode = No Controller in Hard Secure Mode = Yes Key Update Pending = No Remaining Secure Boot Key Slots = 7 Security Protocol properties : ============================ Security Protocol = None Drive Groups = 1 TOPOLOGY : ======== ----------------------------------------------------------------------------- DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR ----------------------------------------------------------------------------- 0 - - - - RAID0 Optl N 111.281 GB dflt N N dflt N N 0 0 - - - RAID0 Optl N 111.281 GB dflt N N dflt N N 0 0 0 14:1 0 DRIVE Onln N 111.281 GB dflt N N dflt - N ----------------------------------------------------------------------------- DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Optl=Optimal|Dgrd=Degraded Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present TR=Transport Ready Virtual Drives = 1 VD LIST : ======= --------------------------------------------------------------- DG/VD TYPE State Access Consist Cache Cac sCC Size Name --------------------------------------------------------------- 0/0 RAID0 Optl RW Yes NRWTD - ON 111.281 GB --------------------------------------------------------------- VD=Virtual Drive| DG=Drive Group|Rec=Recovery Cac=CacheCade|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded Optl=Optimal|dflt=Default|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady B=Blocked|Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled Check Consistency Physical Drives = 2 PD LIST : ======= ------------------------------------------------------------------------------------------------------ EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type ------------------------------------------------------------------------------------------------------ 14:0 1 UGood - 59.125 GB SATA SSD N N 512B TS64GMTS400S U - 14:1 0 Onln 0 111.281 GB NVMe SSD N N 512B ATP NVMe M.2 2280 SSD U - ------------------------------------------------------------------------------------------------------ EID=Enclosure Device ID|Slt=Slot No|DID=Device ID|DG=DriveGroup DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare UBad=Unconfigured Bad|Sntze=Sanitize|Onln=Online|Offln=Offline|Intf=Interface Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign UGUnsp=UGood Unsupported|UGShld=UGood shielded|HSPShld=Hotspare shielded CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded UBUnsp=UBad Unsupported|Rbld=Rebuild Enclosures = 1 Enclosure LIST : ============== ------------------------------------------------------------------------ EID State Slots PD PS Fans TSs Alms SIM Port# ProdID VendorSpecific ------------------------------------------------------------------------ 14 OK 2 2 0 0 0 0 0 - VirtualSES ------------------------------------------------------------------------ EID=Enclosure Device ID | PD=Physical drive count | PS=Power Supply count TSs=Temperature sensor count | Alms=Alarm count | SIM=SIM Count | ProdID=Product ID
Autor: Bastian Stockinger Bastian Stockinger arbeitet im Product Management Team von Thomas-Krenn.
|
Das könnte Sie auch interessieren
Aktivieren oder Deaktivieren des X10DRC-LN4+ onboard LSI SAS 3108 Controllers
MegaRAID FastPath
MegaRAID RAID 0 mit einem Laufwerk erstellen