Adaptec arcconf CLI
Adaptec RAID Controller können mit dem arcconf CLI über die Kommandozeile verwaltet werden. Dieser Artikel zeigt, welche arcconf Kommandos verfügbar sind und wie einige wichtige Kommandos verwendet werden können.
arcconf Kommandos allgemein
Die folgende Auflistung zeigt die verfügbaren Kommandos von arcconf Version 3.03:
$ sudo ./arcconf Controllers found: 1 | UCLI | Microsemi Adaptec uniform command line interface | UCLI | Version 3.03.00 (23668) | UCLI | (C) Microsemi Corporation 2003-2019 | UCLI | All Rights Reserved ATAPASSWORD | setting password on a physical drive CONSISTENCYCHECK | toggles the controller background consistency check mode CREATE | creates a logical device DELETE | deletes one or more logical devices EXPANDERLIST | lists the expanders connected to the controller EXPANDERUPGRADE | updates expander firmware GETCONFIG | prints controller information GETLOGS | gets controller log information GETSMARTSTATS | gets the SMART statistics GETSTATUS | displays the status of running tasks GETVERSION | prints version information for all controllers IDENTIFY | blinks LEDS on device(s) connected to a controller IMAGEUPDATE | update physical device firmware KEY | installs a Feature Key onto a controller LIST | lists all controllers connected to the system MODIFY | performs RAID Level Migration or Online Capacity Expansion PHYERRORLOG | displays PHY error logs for controller or device or an expander PHY PLAYCONFIG | apply the configurations on controller(s) from input XML RESCAN | checks for new or removed drives RESETSTATISTICSCOUNTERS | resets the controller statistics counters ROMUPDATE | updates controller firmware SAVECONFIG | saves the controller(s) information XML file SAVESUPPORTARCHIVE | saves the support archive SETARRAYPARAM | sets the parameters of an array SETBOOT | marks a device bootable SETCACHE | adjusts physical or logical device cache mode SETCONFIG | restores the default configuration SETCONNECTORMODE | changes connector mode settings SETCONTROLLERMODE | changes Controller mode settings SETCONTROLLERPARAM | sets the parameters of the controller SETMAXCACHE | adjusts maxCache settings for physical or logical device SETNAME | renames a logical device given its logical device number SETPERFORM | changes adapter settings based on application SETPOWER | power settings for controller or logical device SETPRIORITY | changes specific or global task priority SETSTATE | manually sets the state of a physical or logical device SETSTATSDATACOLLECTION | toggles the controller statistics data collection modes SLOTCONFIG | lists devices attached to each Slot in an Enclosure SMP | sends SMP Commands to Expander SPLITMIRROR | manages splitting and backup of a mirror TASK | performs a task which is applicable on a physical or logical device UNINIT | manually uninitializes the physical devices which are raw or ready
arcconf romupdate
Mittels arcconf romupdate kann die Firmware eines RAID Controllers aktualisiert werden, z.B.:
arcconf romupdate [CONTROLLERNUMMER] [ROMFILE]
arcconf create
Mittels arcconf create können unter anderem Logical Drives erstellt werden:
$ sudo ./arcconf CREATE
Controllers found: 1
Usage: CREATE <Controller#> LOGICALDRIVE [Options] <Size> <RAID#> <Channel# ID#> [Channel# ID#] ... [noprompt] [nologs]
Usage: CREATE <Controller#> LOGICALDRIVE [Options] <Size> <RAID#> ARRAY <Array#>[noprompt] [nologs]
Usage: CREATE <Controller#> MAXCACHE [options] DataLD <LogicalDrive#> <Size> <RAID#> <Channel# ID#> [Channel# ID#] ... [noprompt] [nologs]
Usage: CREATE <Controller#> MAXCACHE [Options] DataLD <LogicalDrive#> <Size> <RAID#> ARRAY <Array#>[noprompt] [nologs]
Usage: CREATE <Controller#> RAIDZEROARRAY <Channel# ID#> [Channel# ID#] ... [noprompt] [nologs]
Usage: CREATE <Controller#> RAIDZEROARRAY ALL [noprompt] [nologs]
Example: CREATE 1 LOGICALDRIVE stripesize 1024 0 0 0 0 1
Example: CREATE 1 LOGICALDRIVE 1024 1 ARRAY 0
Example: CREATE 1 LOGICALDRIVE stripesize 16 method build MAX 5 0 0 0 1 0 2
Example: CREATE 1 MAXCACHE Wcache WB cachelinesize 64 datald 0 17000 1 0 0 0 1
Example: CREATE 1 MAXCACHE datald 0 17000 0 ARRAY 0
Example: CREATE 1 RAIDZEROARRAY 0 0 0 1 0 2
Example: CREATE 1 RAIDZEROARRAY ALL
===================================================================================
Create a new logical device
Options: Additional creation specifiers.
Stripesize <STRIPE>: Optional parameter for specifying a stripe size.
STRIPE is specified in kilobytes.
16, 32, 64, 128*, 256, 512 and 1024 are supported.
Legs <LEG>: Optional parameter for specifying number of sub-logical devices.
LEG is the number of sub-logical devices for RAID level 50 or 60. Default value is 2.
Name <NAME>: Optional parameter for specifying the name of the logical
device.
Some controllers do not support this parameter.
Method <METHOD>: Initialization method for the logical device.
Valid options include: BUILD and DEFAULT.
Wcache <WCACHE>: Write Cache setting for the logical device. Applicable only with maxCache creation.
Valid options are: WT, WB
WT: write-through (Disabled)
WB: write-back (Enabled)
LDcache <LDCACHE>: Cache setting for the logical device.
Valid options are: LON and LOFF
SSDOverProvisioningOptimization <enable | disable>: Specifies to initialize solid state drives that
support rapid parity initialization feature.
CacheLineSize <CACHELINESIZE>: Specifies the cache line size(KB) for maxCache.
Adjusting cache line size can impact maxCache performance and
maximum size supported. Larger cache line size can support larger
maxCache size. Default value for this parameter is 64.
Valid options can be 64, 128 and 256 based on controller support..
DataLD <LogicalDrive#>: Specifies the existing data logical device number to associate
with the newly created cache logical device.
Size: Size of the logical device in megabytes.
Use MAX to set size to all remaining available space.
Use MAXMBR to set the size to 2TB.
Raid#: Raid level for the new logical device.
0, 1, 1ADM, 10, 10ADM, 5, 6, 50 and 60 are supported.
Channel# ID#: A list of space-delimited channel number and
device number pairs for each device to add
to the logical device.
ARRAY <Array#>: The Array number on which the logical device needs to be created.
RAIDZEROARRAY: Create arrays from list of physical device(s) specified.
Each array will contain exactly one physical device and one RAID 0 logical device.
Default values will be applied for all logical device(s) created.
ALL: Create arrays form list of physical device(s) connected to controller.
noprompt: Don't prompt for confirmation.
* default parameter in MOST circumstances
arcconf getconfig
Mittels arcconf getconfig können umfangreiche Informationen zum RAID Controller sowie zu den konfigurierten RAID Arrays und Logical Drives abgerufen werden:
tk@x11dpi:~$ sudo ./arcconf GETCONFIG 1
Controllers found: 1
----------------------------------------------------------------------
Controller information
----------------------------------------------------------------------
Controller Status : Optimal
Controller Mode : RAID (Hide RAW)
Channel description : SCSI
Controller Model : Adaptec SmartRAID 3152-8i
Controller Serial Number : 8A26F3000CF
Controller World Wide Name : 50000D1E001A8110
Physical Slot : 6
Temperature : 40 C/ 104 F (Normal)
Host bus type : PCIe 3.0
Host bus speed : 7880 MBps
Host bus link width : 8 bit(s)/link(s)
PCI Address (Bus:Device:Function) : 0:af:0:0
Number of Ports : 2
Internal Port Count : 2
External Port Count : 0
Defunct disk drive count : 0
NCQ status : Enabled
Queue Depth : Automatic
Monitor and Performance Delay : 60 minutes
Elevator Sort : Enabled
Degraded Mode Performance Optimization : Disabled
Latency : Disabled
Statistics data collection mode : Disabled
Post Prompt Timeout : 0 seconds
Boot Controller : False
Primary Boot Volume : None
Secondary Boot Volume : None
Driver Name : smartpqi
Driver Supports SSD I/O Bypass : Yes
Manufacturing Part Number : Not Applicable
Manufacturing Spare Part Number : Not Applicable
Manufacturing Wellness Log : Not Applicable
NVRAM Checksum Status : Passed
Sanitize Lock Setting : None
--------------------------------------------------------
Power Settings
--------------------------------------------------------
Power Consumption : 6460 milliWatts
Current Power Mode : Maximum Performance
Pending Power Mode : Not Applicable
Survival Mode : Enabled
--------------------------------------------------------
I2C Settings
--------------------------------------------------------
I2C Address : 0xDE
I2C Clock Speed : 400 KHZ
I2C Clock Stretching : Enabled
--------------------------------------------------------
Cache Properties
--------------------------------------------------------
Cache Status : Not Configured
Cache Serial Number : Not Applicable
Cache memory : 1808 MB
Read Cache Percentage : 100 percent
Write Cache Percentage : 0 percent
No-Battery Write Cache : Disabled
Wait for Cache Room : Disabled
Write Cache Bypass Threshold Size : 1040 KB
--------------------------------------------------------
Green Backup Information
--------------------------------------------------------
Backup Power Status : Ok
Battery/Capacitor Pack Count : 1
Hardware Error : No Error
--------------------------------------------------------
Physical Drive Write Cache Policy Information
--------------------------------------------------------
Configured Drives : Default
Unconfigured Drives : Default
HBA Drives : Default
--------------------------------------------------------
maxCache Properties
--------------------------------------------------------
maxCache Version : 4
maxCache RAID5 WriteBack Enabled : Enabled
--------------------------------------------------------
RAID Properties
--------------------------------------------------------
Logical devices/Failed/Degraded : 1/0/0
Spare Activation Mode : Disabled
Background consistency check : Idle
Consistency Check Delay : 3 seconds
Parallel Consistency Check Supported : Enabled
Parallel Consistency Check Count : 1
Inconsistency Repair Policy : Disabled
Consistency Check Inconsistency Notify : Disabled
Rebuild Priority : High
Expand Priority : Medium
--------------------------------------------------------
Controller Version Information
--------------------------------------------------------
Firmware : 2.62[0]
Driver : Linux 1.2.4-070
Hardware Revision : B
--------------------------------------------------------
Temperature Sensors Information
--------------------------------------------------------
Sensor ID : 0
Current Value : 30 deg C
Max Value Since Powered On : 35 deg C
Location : Inlet Ambient
Sensor ID : 1
Current Value : 40 deg C
Max Value Since Powered On : 41 deg C
Location : ASIC
Sensor ID : 2
Current Value : 33 deg C
Max Value Since Powered On : 38 deg C
Location : Top
Sensor ID : 3
Current Value : 35 deg C
Max Value Since Powered On : 40 deg C
Location : Bottom
--------------------------------------------------------
Connector information
--------------------------------------------------------
Connector #0
Connector Name : CN0
Functional Mode : RAID (Hide RAW)
Connector Location : Internal
SAS Address : 50000D1E001A8110
Connector #1
Connector Name : CN1
Functional Mode : RAID (Hide RAW)
Connector Location : Internal
SAS Address : 50000D1E001A8114
----------------------------------------------------------------------
Array Information
----------------------------------------------------------------------
Array Number 0
Name : A
Status : Ok
Interface : SATA SSD
Total Size : 305276 MB
Unused Size : 3 MB
Block Size : 512 Bytes
Array Utilization : 100.00% Used, 0.00% Unused
Type : Data
Transformation Status : Not Applicable
Spare Rebuild Mode : Dedicated
SSD I/O Bypass : Enabled
--------------------------------------------------------
Array Logical Device Information
--------------------------------------------------------
Logical 0 : Optimal (5, Data, 228858 MB) Logical Drive 1
--------------------------------------------------------
Array Physical Device Information
--------------------------------------------------------
Device 0 : Present (76319MB, SATA, SSD, Channel:0, Device:0) BTWL326004NP080KGN
Device 1 : Present (76319MB, SATA, SSD, Channel:0, Device:1) CVWL411400W1080KGN
Device 2 : Present (76319MB, SATA, SSD, Channel:0, Device:2) CVWL411401LW080KGN
Device 3 : Present (76319MB, SATA, SSD, Channel:0, Device:3) BTWL326403PS080KGN
----------------------------------------------------------------------
Logical device information
----------------------------------------------------------------------
Logical Device number 0
Logical Device name : Logical Drive 1
Disk Name : /dev/sda
Block Size of member drives : 512 Bytes
Array : 0
RAID level : 5
Status of Logical Device : Optimal
Parity Initialization Status : Completed
Size : 228858 MB
Stripe-unit size : 256 KB
Full Stripe Size : 768 KB
Interface Type : SATA SSD
Device Type : Data
Boot Type : None
Heads : 255
Sectors Per Track : 32
Cylinders : 57439
Caching : Disabled
Mount Points : / 228344 MB Partition Number 2 /boot/efi 512 MB Partition Number 1
LD Acceleration Method : SSD IO Bypass
Volume Unique Identifier : 600508B1001C2719FE34EA7308BB236E
--------------------------------------------------------
Array Physical Device Information
--------------------------------------------------------
Device 0 : Present (76319MB, SATA, SSD, Channel:0, Device:0) BTWL326004NP080KGN
Device 1 : Present (76319MB, SATA, SSD, Channel:0, Device:1) CVWL411400W1080KGN
Device 2 : Present (76319MB, SATA, SSD, Channel:0, Device:2) CVWL411401LW080KGN
Device 3 : Present (76319MB, SATA, SSD, Channel:0, Device:3) BTWL326403PS080KGN
----------------------------------------------------------------------
Physical Device information
----------------------------------------------------------------------
Channel #0:
Device #0
Device is a Hard drive
State : Online
Drive has stale RIS data : False
Block Size : 512 Bytes
Physical Block Size : 512 Bytes
Transfer Speed : SATA 6.0 Gb/s
Reported Channel,Device(T:L) : 0,0(0:0)
Reported Location : Enclosure Direct Attached, Slot 0(Connector 0:CN0)
Array : 0
Vendor : ATA
Model : INTEL SSDSC2BB08
Firmware : D2010355
Serial number : BTWL326004NP080KGN
World-wide name : 30000D1E001A8110
Reserved Size : 32768 KB
Used Size : 76287 MB
Unused Size : 0 MB
Total Size : 76319 MB
S.M.A.R.T. : No
S.M.A.R.T. warnings : 0
SSD : Yes
NCQ supported : Supported
NCQ status : Enabled
Boot Type : None
Current Temperature : 23 deg C
Maximum Temperature : 33 deg C
Threshold Temperature : 70 deg C
PHY Count : 1
Drive Configuration Type : Data
Drive Encryption Capability : None
Drive Encryption Status : Not Applicable
Drive Exposed to OS : False
Sanitize Erase Support : True
Sanitize Lock Freeze Support : True
Sanitize Lock Anti-Freeze Support : False
Sanitize Lock Setting : None
Usage Remaining : 85 percent
Estimated Life Remaining : 477
SSD Smart Trip Wearout : False
56 Day Warning Present : False
Drive Unique ID : 65BDF03610F9EA54
Last Failure Reason : No Failure
----------------------------------------------------------------
Device Phy Information
----------------------------------------------------------------
Phy #0
Negotiated Physical Link Rate : 6 Gbps
Negotiated Logical Link Rate : 6 Gbps
Maximum Link Rate : 6 Gbps
----------------------------------------------------------------
Device Error Counters
----------------------------------------------------------------
Aborted Commands : 0
Bad Target Errors : 0
Ecc Recovered Read Errors : 0
Failed Read Recovers : 0
Failed Write Recovers : 0
Format Errors : 0
Hardware Errors : 0
Hard Read Errors : 0
Hard Write Errors : 0
Hot Plug Count : 0
Media Failures : 0
Not Ready Errors : 0
Other Time Out Errors : 0
Predictive Failures : 0
Retry Recovered Read Errors : 0
Retry Recovered Write Errors : 0
Scsi Bus Faults : 0
Sectors Reads : 146752015
Sectors Written : 19244830
Service Hours : 5
Device #1
Device is a Hard drive
State : Online
Drive has stale RIS data : False
Block Size : 512 Bytes
Physical Block Size : 4K Bytes
Transfer Speed : SATA 6.0 Gb/s
Reported Channel,Device(T:L) : 0,1(1:0)
Reported Location : Enclosure Direct Attached, Slot 1(Connector 0:CN0)
Array : 0
Vendor : ATA
Model : INTEL SSDSC2BB08
Firmware : D2010370
Serial number : CVWL411400W1080KGN
World-wide name : 30000D1E001A8112
Reserved Size : 32768 KB
Used Size : 76287 MB
Unused Size : 0 MB
Total Size : 76319 MB
S.M.A.R.T. : No
S.M.A.R.T. warnings : 0
SSD : Yes
NCQ supported : Supported
NCQ status : Enabled
Boot Type : None
Current Temperature : 24 deg C
Maximum Temperature : 34 deg C
Threshold Temperature : 70 deg C
PHY Count : 1
Drive Configuration Type : Data
Drive Encryption Capability : None
Drive Encryption Status : Not Applicable
Drive Exposed to OS : False
Sanitize Erase Support : True
Sanitize Lock Freeze Support : True
Sanitize Lock Anti-Freeze Support : True
Sanitize Lock Setting : None
Usage Remaining : 83 percent
Estimated Life Remaining : 203
SSD Smart Trip Wearout : False
56 Day Warning Present : False
Drive Unique ID : B411C900D2949A6B
Last Failure Reason : No Failure
----------------------------------------------------------------
Device Phy Information
----------------------------------------------------------------
Phy #0
Negotiated Physical Link Rate : 6 Gbps
Negotiated Logical Link Rate : 6 Gbps
Maximum Link Rate : 6 Gbps
----------------------------------------------------------------
Device Error Counters
----------------------------------------------------------------
Aborted Commands : 0
Bad Target Errors : 0
Ecc Recovered Read Errors : 0
Failed Read Recovers : 0
Failed Write Recovers : 0
Format Errors : 0
Hardware Errors : 0
Hard Read Errors : 0
Hard Write Errors : 0
Hot Plug Count : 0
Media Failures : 0
Not Ready Errors : 0
Other Time Out Errors : 0
Predictive Failures : 0
Retry Recovered Read Errors : 0
Retry Recovered Write Errors : 0
Scsi Bus Faults : 0
Sectors Reads : 146548145
Sectors Written : 19444197
Service Hours : 5
Device #2
Device is a Hard drive
State : Online
Drive has stale RIS data : False
Block Size : 512 Bytes
Physical Block Size : 4K Bytes
Transfer Speed : SATA 6.0 Gb/s
Reported Channel,Device(T:L) : 0,2(2:0)
Reported Location : Enclosure Direct Attached, Slot 2(Connector 0:CN0)
Array : 0
Vendor : ATA
Model : INTEL SSDSC2BB08
Firmware : D2010370
Serial number : CVWL411401LW080KGN
World-wide name : 30000D1E001A8111
Reserved Size : 32768 KB
Used Size : 76287 MB
Unused Size : 0 MB
Total Size : 76319 MB
S.M.A.R.T. : No
S.M.A.R.T. warnings : 0
SSD : Yes
NCQ supported : Supported
NCQ status : Enabled
Boot Type : None
Current Temperature : 23 deg C
Maximum Temperature : 34 deg C
Threshold Temperature : 70 deg C
PHY Count : 1
Drive Configuration Type : Data
Drive Encryption Capability : None
Drive Encryption Status : Not Applicable
Drive Exposed to OS : False
Sanitize Erase Support : True
Sanitize Lock Freeze Support : True
Sanitize Lock Anti-Freeze Support : True
Sanitize Lock Setting : None
Usage Remaining : 85 percent
Estimated Life Remaining : 477
SSD Smart Trip Wearout : False
56 Day Warning Present : False
Drive Unique ID : 396B5978CB399100
Last Failure Reason : No Failure
----------------------------------------------------------------
Device Phy Information
----------------------------------------------------------------
Phy #0
Negotiated Physical Link Rate : 6 Gbps
Negotiated Logical Link Rate : 6 Gbps
Maximum Link Rate : 6 Gbps
----------------------------------------------------------------
Device Error Counters
----------------------------------------------------------------
Aborted Commands : 0
Bad Target Errors : 0
Ecc Recovered Read Errors : 0
Failed Read Recovers : 0
Failed Write Recovers : 0
Format Errors : 0
Hardware Errors : 0
Hard Read Errors : 0
Hard Write Errors : 0
Hot Plug Count : 0
Media Failures : 0
Not Ready Errors : 0
Other Time Out Errors : 0
Predictive Failures : 0
Retry Recovered Read Errors : 0
Retry Recovered Write Errors : 0
Scsi Bus Faults : 0
Sectors Reads : 146268907
Sectors Written : 19719974
Service Hours : 5
Device #3
Device is a Hard drive
State : Online
Drive has stale RIS data : False
Block Size : 512 Bytes
Physical Block Size : 512 Bytes
Transfer Speed : SATA 6.0 Gb/s
Reported Channel,Device(T:L) : 0,3(3:0)
Reported Location : Enclosure Direct Attached, Slot 3(Connector 0:CN0)
Array : 0
Vendor : ATA
Model : INTEL SSDSC2BB08
Firmware : D2010355
Serial number : BTWL326403PS080KGN
World-wide name : 30000D1E001A8113
Reserved Size : 32768 KB
Used Size : 76287 MB
Unused Size : 0 MB
Total Size : 76319 MB
S.M.A.R.T. : No
S.M.A.R.T. warnings : 0
SSD : Yes
NCQ supported : Supported
NCQ status : Enabled
Boot Type : None
Current Temperature : 23 deg C
Maximum Temperature : 34 deg C
Threshold Temperature : 70 deg C
PHY Count : 1
Drive Configuration Type : Data
Drive Encryption Capability : None
Drive Encryption Status : Not Applicable
Drive Exposed to OS : False
Sanitize Erase Support : True
Sanitize Lock Freeze Support : True
Sanitize Lock Anti-Freeze Support : False
Sanitize Lock Setting : None
Usage Remaining : 88 percent
Estimated Life Remaining : 608
SSD Smart Trip Wearout : False
56 Day Warning Present : False
Drive Unique ID : F49D909CA0355AE4
Last Failure Reason : No Failure
----------------------------------------------------------------
Device Phy Information
----------------------------------------------------------------
Phy #0
Negotiated Physical Link Rate : 6 Gbps
Negotiated Logical Link Rate : 6 Gbps
Maximum Link Rate : 6 Gbps
----------------------------------------------------------------
Device Error Counters
----------------------------------------------------------------
Aborted Commands : 0
Bad Target Errors : 0
Ecc Recovered Read Errors : 0
Failed Read Recovers : 0
Failed Write Recovers : 0
Format Errors : 0
Hardware Errors : 0
Hard Read Errors : 0
Hard Write Errors : 0
Hot Plug Count : 0
Media Failures : 0
Not Ready Errors : 0
Other Time Out Errors : 0
Predictive Failures : 0
Retry Recovered Read Errors : 0
Retry Recovered Write Errors : 0
Scsi Bus Faults : 0
Sectors Reads : 146343944
Sectors Written : 19673835
Service Hours : 5
Channel #2:
Device #1
Device is an Enclosure Services Device
Reported Channel,Device(T:L) : 2,1(1:0)
Enclosure ID : 0
Enclosure Logical Identifier : 50000D1E001A8118
Type : SES2
Vendor : Adaptec
Model : Virtual SGPIO
Firmware : 2.62
Status of Enclosure Services Device
Speaker status : Not Available
----------------------------------------------------------------------
maxCache information
----------------------------------------------------------------------
No maxCache Array found
----------------------------------------------------------------------
Connector information
----------------------------------------------------------------------
Connector #0
Connector Name : CN0
Functional Mode : RAID (Hide RAW)
Connector Location : Internal
SAS Address : 50000D1E001A8110
Connector #1
Connector Name : CN1
Functional Mode : RAID (Hide RAW)
Connector Location : Internal
SAS Address : 50000D1E001A8114
Command completed successfully.
Weitere Informationen
- Microsemi Smart Storage Controllers User's Guide ARCCONF Command Line Utility (v3.03) (download.adaptec.com, PDF)
|
Autor: Werner Fischer Werner Fischer arbeitet im Product Management Team von Thomas-Krenn. Er evaluiert dabei neueste Technologien und teilt sein Wissen in Fachartikeln, bei Konferenzen und im Thomas-Krenn Wiki. Bereits 2005 - ein Jahr nach seinem Abschluss des Studiums zu Computer- und Mediensicherheit an der FH Hagenberg - heuerte er beim bayerischen Server-Hersteller an. Als Öffi-Fan nutzt er gerne Bus & Bahn und genießt seinen morgendlichen Spaziergang ins Büro.
|