In diesem Artikel finden Sie Informationen zum Broadcom 9540-2M2 M.2 RAID Controller. Der RAID Controller basiert so wie der MegaRAID 9540-8i auf dem Broadcom SAS3808 Chip - bietet aber durch seine beiden M.2 Slots die Möglichkeit eines Hardware-RAIDs ohne dabei HotSwap-Einschübe zu belegen.

Allgemeine Informationen

  • Schnittstelle: TriMode SATA & NVMe / PCIe 4.0 x8
  • Bauhöhe: Low Profile (Slot-Blech für Low Profile und Full Profile enthalten)
  • M.2 Socket: 2x (supporting 22110, 2280, 2260, 2242 & 2230)
  • RAID erstellen: siehe RAID erstellen mit StorCLI

Modelle

9540-2M2
IC Family SAS3808

I/O controller (IOC)

M.2 Ports 2
Cache -
RAID-Level 0, 1
VMware IO HCL ID 57656
Windows Server Catalog 9540-2M2
IDs VID 1000
DID 10e6
SVID 1000
SSID 40e0

Programmausgaben

lspci

# lspci -vvv -nn -s
51:00.0 RAID bus controller [0104]: Broadcom / LSI MegaRAID 12GSAS/PCIe Secure SAS38xx [1000:10e6]
	Subsystem: Broadcom / LSI MegaRAID 12GSAS/PCIe Secure SAS38xx [1000:40e0]
	Physical Slot: 85
	Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+
	Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx-
	Latency: 0, Cache Line Size: 32 bytes
	Interrupt: pin A routed to IRQ 18
	NUMA node: 0
	Region 0: Memory at 20bfffe00000 (64-bit, prefetchable) [size=1M]
	Region 2: Memory at 20bfffd00000 (64-bit, prefetchable) [size=1M]
	Region 4: Memory at d0e00000 (32-bit, non-prefetchable) [size=1M]
	Region 5: I/O ports at a000 [size=256]
	Expansion ROM at d0d00000 [disabled] [size=1M]
	Capabilities: [40] Power Management version 3
		Flags: PMEClk- DSI- D1+ D2+ AuxCurrent=0mA PME(D0-,D1-,D2-,D3hot-,D3cold-)
		Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME-
	Capabilities: [50] MSI: Enable- Count=1/1 Maskable+ 64bit+
		Address: 0000000000000000  Data: 0000
		Masking: 00000000  Pending: 00000000
	Capabilities: [70] Express (v2) Endpoint, MSI 00
		DevCap:	MaxPayload 1024 bytes, PhantFunc 0, Latency L0s unlimited, L1 <64us
			ExtTag+ AttnBtn- AttnInd- PwrInd- RBE+ FLReset+ SlotPowerLimit 0.000W
		DevCtl:	CorrErr- NonFatalErr- FatalErr+ UnsupReq-
			RlxdOrd+ ExtTag+ PhantFunc- AuxPwr- NoSnoop+ FLReset-
			MaxPayload 512 bytes, MaxReadReq 512 bytes
		DevSta:	CorrErr+ NonFatalErr- FatalErr- UnsupReq+ AuxPwr- TransPend-
		LnkCap:	Port #0, Speed 16GT/s, Width x8, ASPM L0s L1, Exit Latency L0s unlimited, L1 <64us
			ClockPM- Surprise- LLActRep- BwNot- ASPMOptComp+
		LnkCtl:	ASPM Disabled; RCB 64 bytes, Disabled- CommClk+
			ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt-
		LnkSta:	Speed 16GT/s (ok), Width x8 (ok)
			TrErr- Train- SlotClk+ DLActive- BWMgmt- ABWMgmt-
		DevCap2: Completion Timeout: Range ABCD, TimeoutDis+ NROPrPrP- LTR-
			 10BitTagComp+ 10BitTagReq- OBFF Not Supported, ExtFmt- EETLPPrefix-
			 EmergencyPowerReduction Not Supported, EmergencyPowerReductionInit-
			 FRS- TPHComp- ExtTPHComp-
			 AtomicOpsCap: 32bit- 64bit- 128bitCAS-
		DevCtl2: Completion Timeout: 260ms to 900ms, TimeoutDis- LTR- OBFF Disabled,
			 AtomicOpsCtl: ReqEn-
		LnkCap2: Supported Link Speeds: 2.5-16GT/s, Crosslink- Retimer+ 2Retimers+ DRS-
		LnkCtl2: Target Link Speed: 16GT/s, EnterCompliance- SpeedDis-
			 Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS-
			 Compliance De-emphasis: -6dB
		LnkSta2: Current De-emphasis Level: -3.5dB, EqualizationComplete+ EqualizationPhase1+
			 EqualizationPhase2+ EqualizationPhase3+ LinkEqualizationRequest-
			 Retimer- 2Retimers- CrosslinkRes: Upstream Port
	Capabilities: [b0] MSI-X: Enable+ Count=128 Masked-
		Vector table: BAR=0 offset=00002000
		PBA: BAR=0 offset=00003000
	Capabilities: [100 v2] Advanced Error Reporting
		UESta:	DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq+ ACSViol-
		UEMsk:	DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq+ ACSViol-
		UESvrt:	DLP+ SDES+ TLP+ FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol-
		CESta:	RxErr- BadTLP- BadDLLP- Rollover- Timeout- AdvNonFatalErr+
		CEMsk:	RxErr- BadTLP- BadDLLP- Rollover- Timeout- AdvNonFatalErr-
		AERCap:	First Error Pointer: 00, ECRCGenCap+ ECRCGenEn- ECRCChkCap+ ECRCChkEn-
			MultHdrRecCap- MultHdrRecEn- TLPPfxPres- HdrLogCap-
		HeaderLog: 00000000 00000000 00000000 00000000
	Capabilities: [148 v1] Power Budgeting <?>
	Capabilities: [158 v1] Alternative Routing-ID Interpretation (ARI)
		ARICap:	MFVC- ACS-, Next Function: 0
		ARICtl:	MFVC- ACS-, Function Group: 0
	Capabilities: [168 v1] Secondary PCI Express
		LnkCtl3: LnkEquIntrruptEn- PerformEqu-
		LaneErrStat: 0
	Capabilities: [188 v1] Physical Layer 16.0 GT/s <?>
	Capabilities: [1b0 v1] Lane Margining at the Receiver <?>
	Capabilities: [248 v1] Vendor Specific Information: ID=0002 Rev=4 Len=100 <?>
	Capabilities: [348 v1] Vendor Specific Information: ID=0001 Rev=1 Len=038 <?>
	Capabilities: [380 v1] Data Link Feature <?>
	Kernel driver in use: megaraid_sas
	Kernel modules: megaraid_sas

storcli

Generating detailed summary of the adapter, it may take a while to complete.

CLI Version = 007.2202.0000.0000 Mar 14, 2022
Operating system = Linux 5.15.0-56-generic
Controller = 0
Status = Success
Description = None


Basics :
======
Controller = 0
Model = MegaRAID 9540-2M2
Serial Number = SPC4607833
Current Controller Date/Time = 02/24/2023, 13:22:23
Current System Date/time = 02/24/2023, 13:22:25
SAS Address = 500062b211c91900
PCI Address = 00:51:00:00
Mfg Date = 11/28/22
Rework Date = 00/00/00
Revision No = 06001


Version :
=======
Firmware Package Build = 52.23.0-4636
Firmware Version = 5.230.01-3723
PSOC FW Version = 0x0006
PSOC Part Number = 14790
NVDATA Version = 5.2300.00-0613
CBB Version = 24.25.01.00
Bios Version = 7.23.00.0_0x07170100
HII Version = 07.23.03.00
HIIA Version = 07.23.03.00
Driver Name = megaraid_sas
Driver Version = 07.717.02.00-rc1


Bus :
===
Vendor Id = 0x1000
Device Id = 0x10E6
SubVendor Id = 0x1000
SubDevice Id = 0x40E0
Host Interface = PCI-E
Device Interface = SAS-12G
Bus Number = 81
Device Number = 0
Function Number = 0
Domain ID = 0


Pending Images in Flash :
=======================
Image name = No pending images


Status :
======
Controller Status = Optimal
Memory Correctable Errors = 0
Memory Uncorrectable Errors = 0
ECC Bucket Count = 0
Any Offline VD Cache Preserved = No
BBU Status = NA
PD Firmware Download in progress = No
Support PD Firmware Download = Yes
Lock Key Assigned = No
Failed to get lock key on bootup = No
Lock key has not been backed up = No
Bios was not detected during boot = No
Controller must be rebooted to complete security operation = No
A rollback operation is in progress = No
At least one PFK exists in NVRAM = No
SSC Policy is WB = No
Controller has booted into safe mode = No
Controller shutdown required = No
Controller has booted into certificate provision mode = No
Current Personality = RAID-Mode 


Supported Adapter Operations :
============================
Rebuild Rate = Yes
CC Rate = Yes
BGI Rate  = Yes
Reconstruct Rate = Yes
Patrol Read Rate = Yes
Alarm Control = No
Cluster Support = No
BBU = NA
Spanning = Yes
Dedicated Hot Spare = Yes
Revertible Hot Spares = Yes
Foreign Config Import = Yes
Self Diagnostic = Yes
Allow Mixed Redundancy on Array = No
Global Hot Spares = Yes
Deny SCSI Passthrough = No
Deny SMP Passthrough = No
Deny STP Passthrough = No
Support more than 8 Phys = Yes
FW and Event Time in GMT = No
Support Enhanced Foreign Import = Yes
Support Enclosure Enumeration = Yes
Support Allowed Operations = Yes
Abort CC on Error = Yes
Support Multipath = Yes
Support Odd & Even Drive count in RAID1E = No
Support Security = Yes
Support Config Page Model = Yes
Support the OCE without adding drives = Yes
Support EKM = Yes
Snapshot Enabled = No
Support PFK = Yes
Support PI = No
Support Ld BBM Info = No
Support Shield State = Yes
Block SSD Write Disk Cache Change = No
Support Suspend Resume BG ops = Yes
Support Emergency Spares = Yes
Support Set Link Speed = Yes
Support Boot Time PFK Change = No
Support JBOD = Yes
Disable Online PFK Change = No
Support Perf Tuning = Yes
Support SSD PatrolRead = Yes
Real Time Scheduler = Yes
Support Reset Now = Yes
Support Emulated Drives = Yes
Headless Mode = Yes
Dedicated HotSpares Limited = No
Point In Time Progress = Yes
Extended LD = No
Support Uneven span  = No
Support Config Auto Balance = No
Support Maintenance Mode = No
Support Diagnostic results = Yes
Support Ext Enclosure = Yes
Support Sesmonitoring = Yes
Support SecurityonJBOD = Yes
Support ForceFlash = Yes
Support DisableImmediateIO = Yes
Support LargeIOSupport = No
Support DrvActivityLEDSetting = Yes
Support FlushWriteVerify = No
Support CPLDUpdate = No
Support ForceTo512e = Yes
Support discardCacheDuringLDDelete = No
Support JBOD Write cache = No
Support Large QD Support = No
Support Ctrl Info Extended = Yes
Support IButton less = Yes
Support AES Encryption Algorithm = No
Support Encrypted MFC = Yes
Support Snapdump = Yes
Support Force Personality Change = No
Support Dual Fw Image = No
Support PSOC Update = Yes
Support Secure Boot = Yes
Support Debug Queue = No
Support Least Latency Mode = No
Support OnDemand Snapdump = Yes
Support Clear Snapdump = Yes
Support FW Triggered Snapdump = Yes
Support PHY current speed = Yes
Support Lane current speed = Yes
Support NVMe Width = Yes
Support Lane DeviceType = Yes
Support Extended Drive performance Monitoring = No
Support NVMe Repair = Yes
Support Platform Security = No
Support None Mode Params = Yes
Support Extended Controller Property = Yes
Support Smart Poll Interval for DirectAttached = Yes
Support Write Journal Pinning = No
Support SMP Passthru with Port Number = Yes
Support SnapDump Preboot Trace Buffer Toggle = No
Support Parity Read Cache Bypass = Yes
Support NVMe Init Error Device ConnectorIndex = No
Support VolatileKey = Yes
Support PSOC Part Information = Yes


Enterprise Key management :
=========================
Capability = Supported
Boot Agent = Not Available
Configured = No


Supported PD Operations :
=======================
Force Online = Yes
Force Offline = Yes
Force Rebuild = Yes
Deny Force Failed = No
Deny Force Good/Bad = No
Deny Missing Replace = No
Deny Clear = No
Deny Locate = No
Support Power State = Yes
Set Power State For Cfg = No
Support T10 Power State = No
Support Temperature = Yes
NCQ = Yes
Support Max Rate SATA = No
Support Degraded Media = No
Support Parallel FW Update = Yes
Support Drive Crypto Erase = Yes
Support SSD Wear Gauge = No
Support Sanitize = No
Support Extended Sanitize = Yes


Supported VD Operations :
=======================
Read Policy = No
Write Policy = No
IO Policy = No
Access Policy = Yes
Disk Cache Policy = Yes
Reconstruction = Yes
Deny Locate = No
Deny CC = No
Allow Ctrl Encryption = No
Enable LDBBM = Yes
Support FastPath = Yes
Performance Metrics = Yes
Power Savings = No
Support Powersave Max With Cache = No
Support Breakmirror = No
Support SSC WriteBack = No
Support SSC Association = No
Support VD Hide = Yes
Support VD Cachebypass = Yes
Support VD discardCacheDuringLDDelete = No
Support VD Scsi Unmap = Yes


Advanced Software Option :
========================

-----------------------------------------
Adv S/W Opt         Time Remaining  Mode 
-----------------------------------------
MegaRAID FastPath   Unlimited       -    
MegaRAID SafeStore  Unlimited       -    
-----------------------------------------

Safe ID =  XQUCARN3BUEP1VM7TW7HRRWVW45RH9N2DTXPLNIZ

HwCfg :
=====
ChipRevision =  A0
BatteryFRU = N/A
Front End Port Count = 0
Backend Port Count = 16
BBU = Absent
Alarm = Absent
Serial Debugger = Present
NVRAM Size = 128KB
Flash Size = 32MB
On Board Memory Size = 0MB
CacheVault Flash Size = NA
TPM = Absent
Upgrade Key = Absent
On Board Expander = Absent
Temperature Sensor for ROC = Present
Temperature Sensor for Controller = Absent
Upgradable CPLD = Absent
Upgradable PSOC = Present
Current Size of CacheCade (GB) = 0
Current Size of FW Cache (MB) = 0
ROC temperature(Degree Celsius) = 39


Policies :
========

Policies Table :
==============

------------------------------------------------
Policy                          Current Default 
------------------------------------------------
Predictive Fail Poll Interval   300 sec         
Interrupt Throttle Active Count 16              
Interrupt Throttle Completion   50 us           
Rebuild Rate                    30 %    30%     
PR Rate                         30 %    30%     
BGI Rate                        30 %    30%     
Check Consistency Rate          30 %    30%     
Reconstruction Rate             30 %    30%     
Cache Flush Interval            4s              
------------------------------------------------

Flush Time(Default) = 4s
Drive Coercion Mode = none
Auto Rebuild = On
Battery Warning = Off
ECC Bucket Size = 15
ECC Bucket Leak Rate (hrs) = 24
Restore Hot Spare on Insertion = Off
Expose Enclosure Devices = On
Maintain PD Fail History = On
Reorder Host Requests = On
Auto detect BackPlane = SGPIO/i2c SEP
Load Balance Mode = Auto
Security Key Assigned = Off
Disable Online Controller Reset = Off
Use drive activity for locate = Off


Boot :
====
BIOS Enumerate VDs = 1
Stop BIOS on Error = Off
Delay during POST = 0
Spin Down Mode = None
Enable Ctrl-R = No
Enable Web BIOS = No
Enable PreBoot CLI = No
Enable BIOS = Yes
Max Drives to Spinup at One Time = 2
Maximum number of direct attached drives to spin up in 1 min = 0
Delay Among Spinup Groups (sec) = 2
Allow Boot with Preserved Cache = Off


High Availability :
=================
Topology Type = None
Cluster Permitted = No
Cluster Active = No


Defaults :
========
Phy Polarity = 0
Phy PolaritySplit = 0
Strip Size = 64 KB
Write Policy = WT
Read Policy = No Read Ahead
Cache When BBU Bad = Off
Cached IO = Off
VD PowerSave Policy = Controller Defined
Default spin down time (mins) = 30
Coercion Mode = None
ZCR Config = Unknown
Max Chained Enclosures = 2
Direct PD Mapping = No
Restore Hot Spare on Insertion = No
Expose Enclosure Devices = Yes
Maintain PD Fail History = Yes
Zero Based Enclosure Enumeration = No
Disable Puncturing = No
EnableLDBBM = Yes
DisableHII = No
Un-Certified Hard Disk Drives = Allow
SMART Mode = Mode 6
Enable LED Header = Yes
LED Show Drive Activity = Yes
Dirty LED Shows Drive Activity = No
EnableCrashDump = No
Disable Online Controller Reset = No
Treat Single span R1E as R10 = No
Power Saving option = Enabled
TTY Log In Flash = Yes
Auto Enhanced Import = Yes
BreakMirror RAID Support = No
Disable Join Mirror = Yes
Enable Shield State = Yes
Time taken to detect CME = 60 sec


Capabilities :
============
Supported Drives = SAS, SATA, NVMe
RAID Level Supported = RAID0, RAID1(2 or more drives), RAID00, RAID10(2 or more drives per span)
Enable JBOD = Yes
Mix in Enclosure = Allowed
Mix of SAS/SATA of HDD type in VD = Allowed
Mix of SAS/SATA of SSD type in VD = Not Allowed
Mix of SSD/HDD in VD = Not Allowed
SAS Disable = No
Max Arms Per VD = 32
Max Spans Per VD = 8
Max Arrays = 32
Max VD per array = 16
Max Number of VDs = 32
Max Parallel Commands = 1517
Max SGE Count = 60
Max Data Transfer Size = 2048 sectors
Max Strips PerIO = 20
Max Configurable CacheCade Size(GB) = 0
Max Transportable DGs = 0
Enable Snapdump = Yes
Enable SCSI Unmap = Yes
Read cache bypass enabled for Parity RAID LDs = Yes
FDE Drive Mix Support = No
Min Strip Size = 64 KB
Max Strip Size = 64 KB


Scheduled Tasks :
===============
Consistency Check Reoccurrence = 168 hrs
Next Consistency check launch = 02/25/2023, 03:00:00
Patrol Read Reoccurrence = 168 hrs
Next Patrol Read launch = 02/25/2023, 03:00:00
Battery learn Reoccurrence = NA
Next Battery Learn = NA
OEMID = Broadcom


Secure Boot :
===========
Secure Boot Enabled = Yes
Controller in Soft Secure Mode = No
Controller in Hard Secure Mode = Yes
Key Update Pending = No
Remaining Secure Boot Key Slots = 7


Security Protocol properties :
============================
Security Protocol = None

Drive Groups = 1

TOPOLOGY :
========

-----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type  State BT       Size PDC  PI SED DS3  FSpace TR 
-----------------------------------------------------------------------------
 0 -   -   -        -   RAID0 Optl  N  111.281 GB dflt N  N   dflt N      N  
 0 0   -   -        -   RAID0 Optl  N  111.281 GB dflt N  N   dflt N      N  
 0 0   0   14:1     0   DRIVE Onln  N  111.281 GB dflt N  N   dflt -      N  
-----------------------------------------------------------------------------

DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Optl=Optimal|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready

Virtual Drives = 1

VD LIST :
=======

---------------------------------------------------------------
DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name 
---------------------------------------------------------------
0/0   RAID0 Optl  RW     Yes     NRWTD -   ON  111.281 GB      
---------------------------------------------------------------

VD=Virtual Drive| DG=Drive Group|Rec=Recovery
Cac=CacheCade|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|dflt=Default|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady
B=Blocked|Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency

Physical Drives = 2

PD LIST :
=======

------------------------------------------------------------------------------------------------------
EID:Slt DID State DG       Size Intf Med SED PI SeSz Model                                    Sp Type 
------------------------------------------------------------------------------------------------------
14:0      1 UGood -   59.125 GB SATA SSD N   N  512B TS64GMTS400S                             U  -    
14:1      0 Onln  0  111.281 GB NVMe SSD N   N  512B ATP NVMe M.2 2280 SSD                    U  -    
------------------------------------------------------------------------------------------------------

EID=Enclosure Device ID|Slt=Slot No|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Sntze=Sanitize|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=UGood Unsupported|UGShld=UGood shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported|Rbld=Rebuild

Enclosures = 1

Enclosure LIST :
==============

------------------------------------------------------------------------
EID State Slots PD PS Fans TSs Alms SIM Port# ProdID     VendorSpecific 
------------------------------------------------------------------------
 14 OK        2  2  0    0   0    0   0 -     VirtualSES                
------------------------------------------------------------------------

EID=Enclosure Device ID | PD=Physical drive count | PS=Power Supply count
TSs=Temperature sensor count | Alms=Alarm count | SIM=SIM Count | ProdID=Product ID


Foto Bastian Stockinger.jpg

Autor: Bastian Stockinger

Bastian Stockinger arbeitet im Product Management Team von Thomas-Krenn.


Das könnte Sie auch interessieren

MegaRAID Firmware mit StorCLI flashen
MegaRAID Storage Manager für VMware ESXi 5.5 Server
VMware ESXi 5.1 und 5.5 zeigen bei MegaRAID Controllern UNCONFIGURED GOOD auch bei konfigurierten Laufwerken