- Optimal performance due to the latest Intel Core 2 Duo technology
- High-quality memory modules of well-known manufacturers. Up to 8GB, based on DDR2-technology possible
- High storage capacity due to SAS/SATA server hard disks, currently up to 8TB possible. Easy exchange of the server hard disks due to Hot-Swap-technology
- High flexibility due to 6 Full-Profile extension slots
- Saving of costs and time due to hardware monitoring via Remote-Management-card
- High reliability thanks to redundant Hot-Swap power supplies (optionally)
|
|
 |
|
|
|
|
|
| CPU |
» Intel® Xeon® 3000 Sequence and Core™ 2 Quad / Duo Series in LGA775
» FSB 1333/1066/800 MHz
» L2 2048 KB |
| RAM |
max. 8GB unbuffered ECC / non-ECC DDR2 800/667 SDRAM |
| Mainboard |
» Supermicro X7SBE
» Intel® 3210 + ICH9R Chipset
» no IDE Controller onboard
» 6x SATA (3 Gbps) onboard (RAID 0,1,5,10 only Windows) |
| Hard disks |
» SATA / SAS
» max. number 8
» Hot-Swap |
| Backplane |
8x Backplane
|
| Chipset |
Intel® 3010 (Mukilteo 2-P) |
| Free slots |
» 1 (x4) PCI-Express, 1 (x8) PCI-Express
» 2x 64-bit 133MHz PCI-X
» 2x 64-bit 100MHz PCI-X |
| LAN |
» 2x RJ45 LAN ports
» 2x Single-port Gigabit PCI-Express Ethernet Controllers
» Intel® 82573V + Intel® 82573L
» Supports 10BASE-T, 100BASE-T, 1000BASE-T, RJ45 output
» IPMI 2.0 (with 3rd LAN optionally) |
| On-Board Peripherals |
» 1x VGA On-board ATI ES1000 (32MB) graphics
» 1x Fast UART 16550 serial port
» Six Serial ATA ports (3 Gbps performance)
» 1 Floppy controller; 1.44 MB
» PS/2 mouse and keyboard
» Up to 7x USB 2.0 / 1.1 compliant ports, 2 rear ports, 2 internal heades for 4 USB 2.0/1.1 ports + 1 on-board |
| Servermanagement |
» Super Doctor III
» web-based tool (independent from place and time)
» no additional hardware required
» allows monitoring of critical system statuses (CPU temperatures, system voltages, fans status etc.)
» cost-saving solution
» automatic e-mail notification
» supports SNMP |
| SATA RAID onboard |
» 6 Ports; RAID 0, 1, 5, 10 support (Windows Only)
Thomas-Krenn technicians recommend the use of an external RAID controller for best performance and stability. |
| Fans |
4x 80x80x30mm (hot swap, interior fans)
2x 80x80x30mm (hot swap, rear panel) |
| Dimensions |
3Ux422x660 mm (HxWxD) |
| Weight |
30 kg (Standard configuration) |
| Volume |
54 dBA (in 1.0 m distance) |
Basis
| Description |
Form factor |
U |
Height |
Width |
Depth |
HDD Slots |
Backplane type |
Drives |
USB-Ports (front) |
USB-Ports (rear) |
Power supply Single |
Power supply redundant |
Extension-slots (FP) |
Fans Hotswap |
Silent-Lüfterkit Option |
(Empty)weight |
Assembly rails |
| 3U Chenbro Chassis RM314 |
19' Rack |
3 U |
132 mm (H) |
430 mm (W) |
660 mm (D) |
8 x HDDs |
SATA/SAS Backplane |
1x 3,25' Floppy, 2x 5,25' Laufwerke |
2 x USB (front) |
2 x USB (rear) |
510 Watt |
3x 350 Watt |
7 x Full Profile |
4x 80x80x30mm (Mitte), 2x 80x80x30mm (Rückwand) |
nein |
30 kg |
optional erhältlich |
| Description |
Chipset |
CPU |
Socket |
max. RAM |
RAM-type |
Banks |
System Bus |
Extension-slot PCI-E (x4) |
Extension-slot PCI-E (x8) |
Extension-slot PCI-X 64-Bit 100MHz |
Extension-slot PCI-X 64-Bit 133MHz |
Form factor |
Onboard SATA Ports |
Onboard SATA Chipset |
Onboard SATA RAID |
NIC-Ports |
NIC-Chipset |
Onboard peripherals |
USB-Ports (rear) |
USB headers |
USB on board |
IPMI Support |
Remote management |
Management software |
| Supermicro Mainboard X7SBE |
Intel 3210 (Bigby-P) |
Celeron S, Intel Xeon 3xxx |
LGA-775 (Single CPU) |
8 GB |
DDR2-667 ECC |
4 DIMMs |
800 MHz, 1066 MHz, 1333 MHz |
1 x PCI-E (x4) |
1 x PCI-E (x8) |
2 x PCI-X 64-Bit 100MHz |
2 x PCI-X 64-Bit 133MHz |
ATX |
6 x SATA |
Intel ICH9R |
Intel Codeset (RAID 0, 1, 5, 10 Windows), Adaptec Codeset (RAID RAID 0, 1, 10 Linux) |
2 x RJ45 |
Intel 82573V, Intel 82573L |
1x Floppy-Controller, 1x VGA (ATI ES1000, 32MB), PS2 Keyboard und Mouse-Port, 1x Fast UART 16550 serial port, 1x internal serial header |
2 x USB (rear) |
2 x USB headers |
1 x USB on Board |
ja |
Supermicro IPMI 2.0;Dedizierte NIC;KVM over LAN;Virtual-Media over LAN |
Supermicro SuperDoctor |
Processor
| Description |
Tact |
Cores |
Cache |
Socket |
Architecture |
FSB |
TDP |
Features |
| Intel Celeron S 430 1.8 GHz |
1.8 GHz |
1 |
512 kB |
LGA-775 (Single CPU) |
65 nm |
800 MHz |
35 W |
Intel EM64T |
| Intel Xeon Dual Core E3110 3.00GHz 6MB FSB1333 |
3 GHz |
2 |
6 MB |
LGA-775 (Single CPU) |
45 nm |
1333 MHz |
65 W |
Intel EM64T, Intel I/OAT, Intel VT |
| Intel Xeon Quad Core 3320 2.50 GHz 6MB FSB1333 |
2.5 GHz |
4 |
6 MB |
LGA-775 (Single CPU) |
45 nm |
1333 MHz |
95 W |
Intel EM64T, Intel I/OAT, Intel VT |
| Intel Xeon Quad Core 3350 2.66GHz 12MB FSB1333 |
2.66 GHz |
4 |
12 MB |
LGA-775 (Single CPU) |
45 nm |
1333 MHz |
95 W |
Intel EM64T, Intel I/OAT, Intel VT |
| Intel Xeon Quad Core 3360 2.83GHz 12MB FSB1333 |
2.83 GHz |
4 |
12 MB |
LGA-775 (Single CPU) |
45 nm |
1333 MHz |
95 W |
Intel EM64T, Intel I/OAT, Intel VT |
Main memory
| Description |
Memory size |
Memory type |
Operating Voltage |
Latency period |
| 512 MB ECC DDR2 667-RAM (1x 512 MB) ATP |
512 MB |
DDR2-667 ECC |
1.8 V |
3 ns |
| 1024 MB ECC DDR2 667-RAM (1x 1024 MB) ATP |
1 GB |
DDR2-667 ECC |
1.8 V |
3 ns |
| 2048 MB ECC DDR2 667-RAM (1x 2048 MB) ATP |
2 GB |
DDR2-667 ECC |
1.8 V |
3 ns |
Hard disks SAS
| Description |
Capacity |
Interface |
Form factor |
Performance |
Revolutions per minute |
Cache |
Latency period |
MTBF |
| 36 GB SAS Fujitsu 15000 rpm |
36 GB |
SAS |
3,5 " |
3 Gb/s |
15000 rpm |
16 MB |
2 ms |
1.2 Mio h |
| 74 GB SAS Fujitsu 15000 rpm |
74 GB |
SAS |
3,5 " |
3 Gb/s |
15000 rpm |
16 MB |
2 ms |
1.4 Mio h |
| 147 GB SAS Fujitsu 15000 rpm |
147 GB |
SAS |
3,5 " |
3 Gb/s |
15000 rpm |
16 MB |
2 ms |
1.4 Mio h |
| 300 GB SAS Fujitsu 15000 rpm |
300 GB |
SAS |
3,5 " |
3 Gb/s |
15000 rpm |
16 MB |
2 ms |
1.4 Mio h |
Hard disks SATA
| Description |
Capacity |
Interface |
Form factor |
Performance |
Revolutions per minute |
Cache |
Latency period |
MTBF |
Features |
| 160 GB SATA II WD Raid Edition II |
160 GB |
SATA |
3,5 " |
3 Gb/s |
7200 rpm |
16 MB |
4.2 ms |
1.2 Mio h |
TLER, RAFF, NCQ |
| 320 GB SATA II WD Raid Edition III |
320 GB |
SATA |
3,5 " |
3 Gb/s |
7200 rpm |
16 MB |
4.2 ms |
1.2 Mio h |
TLER, RAFF, PMR |
| 500 GB SATA II WD Raid Edition III |
500 GB |
SATA |
3,5 " |
3 Gb/s |
7200 rpm |
16 MB |
4.2 ms |
1.2 Mio h |
TLER, RAFF, PMR |
| 750 GB SATA II WD Raid Edition II Green Power |
750 GB |
SATA |
3,5 " |
3 Gb/s |
5400 rpm |
16 MB |
|
1.2 Mio h |
TLER, RAFF |
| 1000 GB SATA II WD Raid Edition III |
1 TB |
SATA |
3,5 " |
3 Gb/s |
7200 rpm |
32 MB |
4.2 ms |
1.2 Mio h |
TLER, RAFF, PMR |
SAS Controller PCI-Express
| Description |
Ports internal |
Ports external |
Cache |
Raid-level |
Bus |
Interface |
Height |
BBU support |
| Adaptec ASR5405 4x SAS (0,1,1E,5,5EE,6,10,50,60) |
4 |
0 |
256 MB |
0, 1, 10, 1E, 5, 50, 6, 60, JBOD, Single Disk |
PCI-E 8x |
SAS, SATA |
LP, FP |
ja |
| Adaptec ASR5805 8x SAS (0,1,1E,5,5EE,6,10,50,60) |
8 |
0 |
512 MB |
0, 1, 10, 1E, 5, 50, 6, 60, JBOD, Single Disk |
PCI-E 8x |
SAS, SATA |
LP, FP |
ja |
| ICP 5125 12x SAS (0,1,1E,5,5EE,6,10,50,60) |
12 |
0 |
256 MB |
0, 1, 1E, 5, 50, 6, 60, JBOD, Single Disk |
PCI-E 8x |
SAS |
FP |
ja |
SATA Controller PCI-Express
| Description |
Ports internal |
Ports external |
Cache |
Raid-level |
Bus |
Interface |
Height |
BBU support |
| 3Ware 9650 4x SATA (0,1,10,5) |
4 |
0 |
256 MB |
0, 1, 10, 5, JBOD, Single Disk |
PCI-E 4x |
SATA |
LP, FP |
ja |
| 3Ware 9650 8x SATA (0,1,5,6,10,50) |
8 |
0 |
256 MB |
0, 1, 10, 5, 50, 6, JBOD, Single Disk |
PCI-E 4x |
SATA |
LP, FP |
ja |
Network card PCI Express
| Description |
Ports |
Bus |
Category |
Medium |
Height |
| Intel PRO/1000 PT Single Port server network card |
1 |
PCI-E 1x |
1 GBit |
Kupfer |
LP, FP |
| Intel PRO/1000 PT Dual Port Server network card |
2 |
PCI-E 4x |
1 GBit |
Kupfer |
LP, FP |
| Intel PRO/1000 PT Quad Port Server network card |
4 |
PCI-E 4x |
1 GBit |
Kupfer |
LP, FP |
additional add-on card PCI Express
| Description |
Ports internal |
Bus |
Interface |
Height |
| Qlogic QLE2460 Single Port Fibre Channel HBA |
1 |
PCI-E 4x |
Fibre |
LP, FP |
| Qlogic QLE2462 Dual Port Fibre Channel HBA |
2 |
PCI-E 4x |
Fibre |
LP, FP |
SAS Controller PCI-X
| Description |
Ports internal |
Raid-level |
Bus |
Interface |
Height |
BBU support |
| LSI 3041X-R 4x SAS/SATA (0,1,1E,10E) |
4 |
0, 1, 1E |
PCI-X 133MHz |
SAS, SATA |
LP, FP |
nein |
Network card PCI-X
| Description |
Ports |
Bus |
Category |
Medium |
Height |
| Intel PRO/1000 MT Dual Port Server network card |
2 |
PCI-X 64Bit 133MHz |
1 GBit |
Kupfer |
LP, FP |
additional add-on card PCI-X
| Description |
Ports internal |
Ports external |
Channels |
Bus |
Interface |
Height |
| Qlogic QLA2460 Single Port Fibre Channel HBA |
1 |
|
|
PCI-X 64Bit 133MHz |
Fibre |
LP, FP |
| Qlogic QLA4052 I-SCSI HBA |
|
2 |
|
PCI-X 64Bit 133MHz |
iSCSI |
LP, FP |
| Adaptec ASC-29320 SCSI Controller |
1 |
1 |
1 |
PCI-X 64Bit 133MHz |
SCSI |
LP, FP |
Remote Management
| Description |
Key features |
| IPMI Remote Management module 2.0 (X7/H8/PDSME+) |
IPMI with KVM Over LAN, Serial Over LAN (SOL), Virtual Media Over LAN (Virtual USB Floppy/CD and Drive Redirection), LAN Alert-SNMP Trap, Event Log, OS Independent, Hardware Health Monitor, Remote Power Control, Support RMCP & RMCP + Protocols |
Die Vorteile von Remote Management auf einen Blick:
» Fernwartung unabhängig vom Betriebssystem
» Kosteneinsparung durch Senkung der TCO
» absolute Verfügbarkeit und damit Zeitersparnis
» einfache Bedienung und Konfiguration, da Zugriff über Standard Webbrowser
» Unterstützung des Systemmanagementstandardes IPMI
» kein spezieller Client auf dem Administrator-PC notwendig
» einfache Installation
|
 |
| |
IPMI Modul X7DBE etc. |
| Slotplatz Belegung |
Nein |
| Auslesen aller Serverdaten (Temperatur, Lüfter etc.) ohne Installation von Software |
Ja |
| E-Mail Benachrichtigung im Fehlerfall |
Ja |
Remotezugriff in
folgenden Betriebszuständen |
Power on/off
Booten
Restart |
| Verlegung/Verbindung von Kabeln notwendig |
Nein |
| Remotezugriff auf BIOS |
Ja |
| unterstütze Betriebssysteme |
Alle |
| Verschlüsselung |
Ja - SSL |
IPMI 2.0 Compliant
|
Ja |
Hardware Monitor
(bei der eRIC Express Remote Card abhängig von der Management-Software des Mainboards) |
CPU, Systemtemperatur,
Stati für Systemlüfter,
CPU-Lüfter und Systemspannung,
SEL Entries
|
benötigt eigene Stromversorgung
|
Nein |
individuelle Rechte
|
Ja - Gruppen,
Benutzerbeschränkung |
Übertragung Videosignale
|
Ja
|
Übertragung Tastatur-
und Maussignale über USB
|
Nein, nur über LAN
|
Zum technischen Datenblatt IPMI Modul: AOC-SIM1U [4 MB]
Battery Backup Unit for your data securityVorteile einer BBU
Eine BBU (Battery Backup Unit) stellt sicher, dass noch nicht geschriebene Daten, die sich aber im Controller Cache befinden, bis zu 72 Stunden nach einem Stromausfall noch vorhanden sind. Durch das Aufrechterhalten der Spannung am Cache können die Daten nach dem Neustarten des Servers noch auf das Volume geschrieben werden und die Konsistenz der Daten ist wieder hergestellt.
Bei aktiviertem Schreib-Cache (höhere Performance) sollten Sie - aus Gründen der Datensicherheit - immer eine BBU verwenden. Backup
| Description |
Interface |
Capacity (native) |
Capacity (comp.) |
Transfer rate (native/comp.) |
MTBF |
Buffer |
Power (operating) |
Power (standby) |
| Streamer LTO2 HH Tandberg 200/400GB SCSI |
SCSI Ultra 160 |
200 GB |
400 GB |
24/48 MB/s |
250000 h |
64 MB |
18 W |
9 W |
| Streamer LTO3 HH Tandberg 400/800GB SCSI |
SCSI Ultra 160 |
400 GB |
800 GB |
60/120 MB/s |
250000 h |
128 MB |
13 W |
|
| Streamer LTO1 HH Tandberg 100/200GB SCSI |
SCSI Ultra 160 |
100 GB |
200 GB |
16/32 MB/s |
250000 h |
64 MB |
18 W |
9 W |
| Description |
Interface |
Transfer rate (native/comp.) |
MTBF |
Power (operating) |
| Tandberg RDX Kit internal with 160 GB Cartridge (removable hard disk) |
SATA 1 |
25-45 MB/s |
500000 h |
7.5 W |
| Tandberg RDX Kit internal with 320 GB Cartridge (removable hard disk) |
SATA 1 |
150 MB/s |
500000 h |
7.5 W |
| Tandberg RDX USB drive external |
USB |
25-45 MB/s |
500000 h |
6.6 W |
| Drive |
Capacity |
Backup rate |
| AIT1 Turbo Streamer Sony 40/100 GB SATA |
40 - 100* GB |
21 - 54* GB/hour |
| AIT2 Turbo Streamer Sony 80/200 GB SCSI |
80 - 200* GB |
43 - 112* GB/hour |
| AIT3 Streamer Sony 100/260GB SCSI |
100 - 260* GB |
42 - 110* GB/hour |
| AIT4 Streamer Sony 200/520GB SCSI |
200 - 520* GB |
85 - 220* GB/hour |
| LTO1 HH Streamer Tandberg 100/200GB SCSI |
100 - 200* GB |
16 - 32* MB/s |
| LTO2 HH Streamer Tandberg 200/400GB SCSI |
200 - 400* GB |
24 - 48* MB/s |
| LTO3 HH Streamer Tandberg 400/800GB SCSI |
400 - 800* GB |
60 - 220* MB/s |
| SAIT1 |
500 - 1300* GB |
105 - 270* MB/s |
| *at max. compression |
Power supply unit
| |
Length |
Width |
Height |
| 510 Watt EPS power supply RM3xx |
24.00 |
10.00 |
9.00 |
| 3x 350 W |
28.50 |
8.20 |
12.00 |
Mounting articles
| Description |
Distance between assembly flanges |
Total length server front to end of assembly rail |
Max. extraction length |
| Extractable assembly rails (2-4 U) screwless |
600-750 mm |
710 mm |
705 mm |
| |
1U |
SC811
|
SR14xx/SR24xx/
SR25xx/RM217 |
SC53xx |
2-4 U |
SMCI-5015 |
Lower shelf |
| Distance between assembly flanges (A) |
630-780 mm |
340-730
|
620-750 |
650-750 |
500-820 |
650-850 |
660-900 |
| Total length server front to end of assembly rail (B) |
630 |
630
|
900 |
800 |
700 |
690 |
- |
Maximal extraction length
out of server cabinet (C) |
650 |
500
|
750 |
750 |
650 |
370 - 695
695 mm only with an adapter (contained in the accessory) |
- |
All information in mm.
If the standard assembly rails do not match into your rack cabinet,
please contact us. We are looking forward to help you.
 Service & Support
| Service-Leistung |
Business |
Premium |
| Laufzeit des Service & Support Vertrages in Monaten |
24 |
36 |
Vor-Ort-Service (Next Business Day)
Die Servicepreise richten sich nach dem Standort des Servers
(Deutschland, Österreich oder Polen), bei Standortveränderung
ist der Kunde verpflichtet, dies der Thomas-Krenn.AG mitzuteilen. |
|
 |
Pickup & Return Service |
 |
 |
Technischer Support (E-Mail) |
 |
 |
Treiber-Support |
 |
 |
Zugriff auf my.thomas-krenn.com |
 |
 |
Knowledgebase |
 |
 |
Online Schulungen |
 |
 |
Express-Vorabaustausch |
 |
 |
30 Tage Installations-Support |
 |
 |
Telefonischer Technischer Support (9 bis 17 Uhr) |
 |
 |
Telefonischer Technischer Support (6 bis 22.30 Uhr) |
|
 |
Zugriff auf Linux Expert-Center |
|
 |
Zugriff auf Microsoft Expert-Center |
|
 |
|
| Weitere Informationen zu unserem Service & Support finden Sie unter my.thomas-krenn.com |
Druckversion als pdf-Datei [300 kB] Pre-installed Linux operating system
Zu Testzwecken werden alle Thomas-Krenn Server mit dem eigens zusammengestellten TK-Kernel in Verbindung mit Debian installiert.
Folgende Punkte gibt es dabei zu beachten
- Das Debian wird ohne grafische Oberfläche installiert
- In der Sources.list sind Thomas Krenn Quellen angegeben, mit denen auch in Zukunft direkt Kernel-Updates gemacht werden können und weitere Pakete zu finden sind, die in den offiziellen Debian-Quellen nicht enthalten sind
Die Partitionierung erfolgt dabei folgendermaßen:
- 5GB Root-Partition
- der restliche Festplattenspeicher bleibt unangetastet
Selbstverständlich erstellen wir auch die Partition nach Ihren Wünschen! Bitte teilen Sie deshalb Ihrem Vertriebansprechpartner direkt diese mit!
|