PRODUCT KEY-FEATURES




  • NAS, iSCSi and Fibre Channel function
  • Volume- and data replication
  • Snapshot- and backup function
  • Support of Windows Active Directory, External LDAP, NIS, Quota
  • 500 Watt redundant power supply (2x 500 Watt)
  • IPMI Management and monitoring
2
PRODUCT SPECIFICATION

CPU

» max. 2x Xeon Quad-Core
» max. FSB 1333
» max. L2 8192KB

RAM » only Registered Memory
» ECC Function
» Max. 32768 MB
» Dual Channel Memory Bus
» DDR2- Fully Buffered DIMM 533/667 MHz
Mainboard » Supermicro X7DBE/8
» Chipset Intel® 5000P
» IDE Controller onboard
» SATA RAID onboard (RAID 0,1,5,10)
» - only MB X7DB8: SCSI RAID onboard (RAID 0,1,10)
» Registered ECC DDR2 Fully Buffered DIMM 533/667/ MHz
Chipset Intel® 5000P (Blackford)
Free slots
» 2x PCI-X (133 MHz), 1x PCI-X (100 MHz)
» 2 (x8) PCI-Express, 1 (x4) PCI-Express
LAN onboard » 2x Gigabit LAN onboard
Input / Output » Dual EIDE channels support up to four UDMA IDE devices
» 2x RJ45 LAN ports
» 2x USB rear ports / 3x USB internal headers / USB 2.0 Compliant / 1.1 Compliant
» 1x VGA Port (ATI ES1000 Graphics, 16MB)
» 1 Fast UART 16550 serial port / 1 Fast UART 16550 serial header
» 1 ECP/EEP parallel port

Servermanagement

» Super Doctor III
» web-based tool (independent from place and time)
» no additional hardware required
» allows control of critical system statuses (CPU temperature, system voltage, fans status etc.)
» cost-saving solution
» automatic e-mail notification
» supports SNMP
Dimensions 2U x 426 x 650 mm (HxWxD)
Weight 24 kg (standard configuration)
Volume 50 dBA (in 1.0 m distance, idling)
60 dBA (in 1.0 m distance, bootling/full load)

3
PRODUCT DETAILS


Basis

Description Chipset CPU Socket max. RAM RAM-type Banks System Bus Extension-slot PCI-E (x4) Extension-slot PCI-E (x8) Extension-slot PCI-X 64-Bit 100MHz Extension-slot PCI-X 64-Bit 133MHz Form factor Onboard SATA Ports Onboard SATA Chipset Onboard SATA RAID NIC-Ports NIC-Chipset Onboard peripherals USB-Ports (rear) USB headers IPMI Support Remote management Management software
Supermicro Mainboard X7DBE (SATA on board) Intel 5000P (Blackford) Intel Xeon 5xxx LGA-771 (Dual CPU) 32 GB FB-DIMM 667 8 DIMMs 800 MHz, 1066 MHz, 1333 MHz 1 x PCI-E (x4) 2 x PCI-E (x8) 1 x PCI-X 64-Bit 100MHz 2 x PCI-X 64-Bit 133MHz Ext. ATX 6 x SATA Intel ESB2 RAID 0, 1, 10, (5 Windows) 2 x RJ45 Intel 82563EB 1x Single EIDE channel (2x IDE Devices), 1x Floppy-Controller, 1x VGA (ATI ES1000, 16MB), PS2 Keyboard und Mouse-Port, 1x Fast UART 16550 serial port, 1x internal serial header 2 x USB (rear) 3 x USB headers ja Supermicro IPMI 2.0 Supermicro SuperDoctor 3

Description Key features
IPMI Remote Management module 2.0 (X7/H8/PDSME+) IPMI with KVM Over LAN, Serial Over LAN (SOL), Virtual Media Over LAN (Virtual USB Floppy/CD and Drive Redirection), LAN Alert-SNMP Trap, Event Log, OS Independent, Hardware Health Monitor, Remote Power Control, Support RMCP & RMCP + Protocols

Description Form factor U Height Width Depth HDD Slots Backplane type USB-Ports (front) USB-Ports (rear) Power supply Single Power supply redundant Extension-slots (LP) Fans Hotswap Fans Non-Hotswap Silent-Lüfterkit Option Airshroud (Empty)weight Assembly rails Distance between assembly flanges Total length server front to end of assembly rail Max. extraction length
2U Supermicro Chassis SC823TQ 19' Rack 2 U 89 mm (H) 426 mm (W) 650 mm (D) 6 x HDDs SATA/SAS Backplane 0 x USB (front) 2 x USB (rear) 500 Watt 2x 500 Watt 7 x Low Profile 4x 80mm 6300 RPM fans - nein ja 24 kg im Lieferumfang enthalten 470-870 mm 750 mm 720 mm

Description Ports internal Ports external Cache Raid-level Bus Interface Height BBU support
Areca Raid Controller ARC-1680-LP 8xSAS (1x internal, 1x external) 4 4 256 MB 0, 1, 10, 1E, 5, 50, 6, 60, JBOD, Single Disk PCI-E 8x SAS, SATA LP ja

Description Memory size Memory type Operating Voltage Latency period
1024 MB DDR2 667-RAM (1x 1024 MB) ATP FB - Dimm 1 GB FB-DIMM 667 1.8 V 3 ns

Description Tact Cores Cache Socket Architecture FSB TDP Features
Intel Quad Core Xeon E5420 2.5 GHz 4 12 MB LGA-771 (Dual CPU) 45 nm 1333 MHz 80 W Intel EM64T, Intel I/OAT, Intel VT

Basic configuration

CPU » 1x Intel Xeon Quad Core E5420 2.50 GHz 12MB FSB1333
RAM » 4096 MB ECC Registered DDR2 667-RAM ATP FB-Dimm (4x 1024 MB)
RAID

» Areca Raid Controller ARC-1680-LP
» Raid Level: 0,1,1E,3,5,6,10,30,50,60 and JBOD
» Intel 800 MHz IOP348 I/O processor
» 256 MB Cache
» Intel Raid Engine for max. performance at Raid6
» Battery Backup Module Support (optionally)
» Write-Trough or Write-Back Cache
» Online Raid-Level Migration
» Online memory extension
» Online Volume-Set enlargement
» Partitions of 2TB due to 64bit LBA support
» Configuration over webbrowser
» E-Mail notification and SNMP support

Hostinterface » 2x Gigabit LAN onboard
» optionally: Areca SAS Controller with 2x external SAS Port
» optionally: Adaptec 29320ALP SCSI HBA
» optionally: Intel PRO/1000 MT Dualport Server Adapter
» optionlly: Qlogic Fibre Channel HBA QLA2460, QLA2462, QLE2460, QLE2462
Energy supply » 2x 500 Watt redundant power supply
Remotemanagement » IPMI Module from Supermicro with IPMI sensor
» Management over IPMI-View software or webbrowser
» no additional hardware required
» allows monitoring of system-critical statuses (CPU temperature, system voltage, fans status)
» cost-saving solution
» automatic e-mail notification
» supports SNMP
Mainboard Supermicro Servermainboard X7DBE with Intel 5000P Chipset
Chassis » Supermicro SC823-TQ with SAS/SATA backplane
» 4x 80mm 6300 RPM fans

SAS Controller PCI-Express

Description Ports internal Ports external Cache Raid-level Bus Interface Height BBU support
Areca Raid Controller ARC-1680-LP 8xSAS (1x internal, 1x external) 4 4 256 MB 0, 1, 10, 1E, 5, 50, 6, 60, JBOD, Single Disk PCI-E 8x SAS, SATA LP ja

additional add-on card PCI Express

Description Ports internal Bus Interface Height
Qlogic QLE2460 Single Port Fibre Channel HBA 1 PCI-E 4x Fibre LP, FP
Qlogic QLE2462 Dual Port Fibre Channel HBA 2 PCI-E 4x Fibre LP, FP

Network card PCI-X

Description Ports Bus Category Medium Height
Intel PRO/1000 MT Dual Port Server network card 2 PCI-X 64Bit 133MHz 1 GBit Kupfer LP, FP

additional add-on card PCI-X

Description Ports internal Ports external Channels Bus Interface Height
Qlogic QLA2460 Single Port Fibre Channel HBA 1     PCI-X 64Bit 133MHz Fibre LP, FP
Qlogic QLA4052 I-SCSI HBA   2   PCI-X 64Bit 133MHz iSCSI LP, FP
Adaptec ASC-29320 SCSI Controller 1 1 1 PCI-X 64Bit 133MHz SCSI LP, FP

Service & Support

Service-Leistung Business Premium
Laufzeit des Service & Support Vertrages in Monaten 24 36
Vor-Ort-Service (Next Business Day)
Die Servicepreise richten sich nach dem Standort des Servers
(Deutschland, Österreich oder Polen), bei Standortveränderung
ist der Kunde verpflichtet, dies der Thomas-Krenn.AG mitzuteilen.
 
Pickup & Return Service
Technischer Support (E-Mail)
Treiber-Support
Zugriff auf my.thomas-krenn.com
Knowledgebase
Online Schulungen
Express-Vorabaustausch
30 Tage Installations-Support
Telefonischer Technischer Support (9 bis 17 Uhr)
Telefonischer Technischer Support (6 bis 22.30 Uhr)  
Zugriff auf Linux Expert-Center  
Zugriff auf Microsoft Expert-Center  
Weitere Informationen zu unserem Service & Support finden Sie unter my.thomas-krenn.com

 Druckversion als pdf-Datei [300 kB]


Operating system

Open-E DSS - Data Storage Server auf Linux Basis

» sofort einsatzbereiter Storage-Server (NAS und iSCSI Funktionalität)
» das Betriebssystem ist auf einem Flash-Modul gespeichert und bietet damit maximale Sicherheit gegenüber Viren und Manipulation
» Unterstützung aller gängigen SATA RAID-Controller


open_e_dss_quickstart_en [120 kB]
open_e_dss_datasheet_de [814 kB]

Feature-Gallery

Login Screen Setting Up IP Address RAID Controller Configuration
 
iSCSI Portal Configuration Creating and Managing iSCSI Targets Volume Groups and Replication Management
 
Snapshots Management Backup Tools Save and Restore System Settings
 
System Software Update Logical Volume Status Connections Status
     
Logs and Running Tasks Status    
   
     
Feature Beschreibung
Standard Gateway Support Open-E iSCSI Enterprise can be used in business environments with structured networks, and it allows for remote management and optional data access via Intranet or Internet.
DHCP Server Support

The Dynamic Host Configuration Protocol (DHCP) is a communications protocol allowing network administrators to centrally manage and automate the process of assigning IP addresses in a network.

Secured Administration Access Open-E iSCSI Enterprise provides Secured Administration Access, requiring administrators to use SSL to access and configure the iSCSI software. Open-E iSCSI Enterprise also allows users to assign different administrator rights to multiple administrators.
Multiple Network Interface Card (NIC) Support

Open-E iSCSI Enterprise supports the use of two or more network cards to access separate sub-networks. It also allows users to select the services to be enabled on a specified NIC.

Adaptive Load Balancing Adaptive load balancing enhances performance by automatically routing data through several alternative paths or storage adapters as application needs change.
Adapter Fault Tolerance

Adapter Fault Tolerance assures greater reliability by providing that a secondary storage adapter automatically takes over if the primary storage adapter fails.

Multi-Snapshot with the scheduling function Multi-Snapshot with the scheduling function, available in Open-E iSCSI Enterprise, allows users to take a snapshot at a specified time (e.g., automatically every hour). If a user accidentally deletes or incorrectly modifies a file, he can still recover the data from a previous snapshot image.
Multiple Logical Volume Groups Logical volume groups allow storage administrators to create logical storage pools that span multiple physical disk drives. With its support of multiple logical volume groups, Open-E iSCSI Enterprise makes it easier to meet the changing needs of users and applications while making the maximum use of available physical disk space.
Read Only LUN option This function lets the user to set the LUN (Logical Unit Number) as a read-only device.
 Volume Replication With Open-E software your data will be save thanks to volume replication. It creates exact copy of source volume in real time, this means that when on one volume data is lost then data on second volume still exists.
Online Logical Volume Expansion Online logical volume expansion allows administrators to change the size of storage volumes as needed without having to restart the application, recreate the volume, and back up and restore the data to the volume.
Multilevel Management OPEN-E iSCSI' multilevel management capabilities allow the assignment of different levels of management rights to different storage managers. This allows, for example, some users or managers to monitor disk utilization for planning purposes without having the right to actually change or add actual storage volumes.
Network Client Support

- Microsoft Windows
- Linux
- UNIX
- Novell Netware 6.5
- Apple OS X

Console Tools The Open-E iSCSI Enterprise management console allows managers to monitor the status of the network, drivers and hardware, as well as to view information about memory usage. They can also control the Ping function, time settings, and DNS and DHCP configuration. Through the console, administrators can also change the language in which they run Open-E iSCSI.
Tuning Tools This option is for advanced administrators. Tuning tools allows increase Open-E server performance. Using this tool you have possibility of enhancing disk, network, services settings.
Hardware Monitoring The Open-E software allows you to monitor hardware status using your motherboard's sensors. This information can be: temperatures, voltages and/or fan speeds.
UPS Support An uninterruptible power supply, which provides safe shutdown in case of power failure, can be attached to an Open-E iSCSI Enterprise system through a standard serial port.
Network UPS OPEN-E iSCSI Enterprise also supports the use of UPS to ensure the smooth shutdown of all OPEN-E iSCSI servers on the network in the case of a power failure. Using the SNMP interface for communication. the UPS-equipped server sends (or receives, if working in slave mode) the power failure signal and will shut down all servers in the network without the loss of data.
Email Notification Open-E iSCSI Enterprise can be configured to send email alerts to the system administrator in case of problems with the Open-E iSCSI software.
Log Function Open-E iSCSI Enterprise allows the storage administrator to transmit error logs or system logs to OPEN-E to aid in diagnostics and troubleshooting.
LCD Panel Support Open-E NAS Enterprise supports the LCD panel (Pyramid LCD Display) as an optional display. Therefore, you don't need a monitor for configuring your NAS server manually.
RAID Interface Support

The OPEN-E iSCSI Enterprise solution can support most hardware ATA / SATA / SCSI RAID controllers of:

- 3ware
- Adaptec
- ICP Vortex
- Intel
- LSI Logic
- more..

InfiniBand Support You can use InfiniBand cards for connecting servers. InfiniBand is modern, high-speed (up to 10Gbit) serial computer bus.
Target Password Support Open-E iSCSI Enterprise allows set up password for targets to protect them from unauthorized access
Multiple CHAP for target Open-E iSCSI Enterprise allows assigning multiple CHAP users that will be granted to access to the target. CHAP user authentication is by user name and password.
CHAP User Management Thanks to this feature you can easy manage users that will have access to the targets. You can create, edit and remove existing CHAP users.
10 Gb Ethernet with TCP/IP Offload (TOE) To improve the data throughput and latency, the Open-E iSCSI Enterprise supports 10 Gbit Ethernet cards from Chelsio for servers and storage systems. Chelsio provides the highest 10GbE performance available. With the on-board hardware that offloads TCP/IP processing from its host system, the Chelsio card lets its host gives more CPU cycles to applications. The result: the system gets increased bandwidth, improved overall performance, and reduced message latency across connections.
Multi-CPU Support The Open-E Enterprise version supports up to 8 CPUs to concurrently execute the Open-E iSCSI. This increases the potential I/O throughput of the disk server and makes it suitable for heavy duty data requirements.
Fibre Channel Support For high bandwidth, best latency and performance, the Open-E iSCSI Enterprise version supports Fibre Channel HBA´s of Emulex and Qlogic. Fibre Channel is the standard connection type for connecting high speed storage devices, like the Open-E iSCSI target, to computers in Storage Area Networks (SAN).
MPIO Support The Open-E iSCSI Enterprise allows set multiple connections to one target increasing performance and reliability.
Proxy settings With Open-E software you can use proxy server for Internet connections.