Adaptec Series 5 RAID Controller 3 Gb

Aus Thomas-Krenn-Wiki
Zur Navigation springen Zur Suche springen

In diesem Artikel finden Sie Informationen zu Adaptec Series 5 (Adaptec Unified Serial SAS/SATA 3 Gb) RAID Controllern.

Allgemeine Informationen

Modelle

RAID Controller Ports
intern
Ports
extern
PCIe Lanes Cache Cache-Schutz RAID-Level Max. Anzahl
SSDs/HDDs bei Verw.
von SAS Expandern
Anmerkungen
Adaptec ASR5405Z 4i 4 - 8 512MB Ja (ZMCP) 0, 1, 10, 1E, 5, 50[1], 6, 60[1], JBOD, Single Disk 256
Adaptec ASR5445Z 4i4e 4 4 8 512MB Ja (ZMCP) 0, 1, 10, 1E, 5, 50, 6, 60 256
Adaptec ASR5805Z 8i 8 - 8 512MB Ja (ZMCP) 0, 1, 10, 1E, 5, 50, 6, 60 256
Adaptec ASR5405 4i 4 - 8 256MB Optional (BBU) 0, 1, 10, 1E, 5, 50[1], 6, 60[1] 256
Adaptec ASR5805 8i 8 - 8 512MB Optional (BBU) 0, 1, 10, 1E, 5, 50, 6, 60 256
Adaptec ASR51245 12i4e 12 4 8 512MB Optional (BBU) 0, 1, 10, 1E, 5, 50, 6, 60 256 enthält SAS Expander
Adaptec ASR51645 16i4e 16 4 8 512MB Optional (BBU) 0, 1, 10, 1E, 5, 50, 6, 60 256 enthält SAS Expander
Adaptec ASR52445 24i4e 24 4 8 512MB Optional (BBU) 0, 1, 10, 1E, 5, 50, 6, 60 256 enthält SAS Expander

Versionsinformationen

Build 18948 (18 May 2012)

  • Release Notes Build 18948, Auszug aus Enhancements and Bug Fixes:
    • Fixed an firmware flash issue with Series 5405Z, 5445Z, 5805Z, and 5805ZQ, where the controller could rendered in operable. For more information on this issue, please consult ASK article #17182.
    • Resolved a cosmetic issue within Adaptec Storage Manager, where the array status would report failed after a Forced Online operation is performed.
    • Fixed an issue with the scrollbar not responding as intended within Adaptec Storage Manager.
    • Added maxCache status to ARCCONF.
    • Resolved a cosmetic issue where the default logical name was incorrect when 10 or more arrays were created at a single time.
    • Added maxCache status indicator, similar to a RAID creation, when a drive is being added to the maxCache pool.

Build 18937 (06 Feb 2012)

  • Release Notes Build 18937, Auszug aus Enhancements and Bug Fixes:
    • Fixed an issue that would cause a bus hang condition after running a rescan using the arcconf utility.
    • Fixed an issue that would prevent a user from creating a second array within the CTRL-A utility.
    • Fixed an issue where drives could drop during a build/verify operation after a warm reboot.
    • Fixed an issue where the drive capacity displayed in the CTRL-A utility was incorrect.

Build 18252 (20 Dec 2010)

  • Release Notes Build 18252, Auszug aus Enhancements and Bug Fixes:
    • Fixed an issue in configurations with maxCache (formerly MaxIQ) enabled, where SSD cache fetches could overlap with host write IOs when array write cache is disabled. Please note that the SSD cache will be reset after this firmware upgrade, which could result in a temporary performance impact as the SSD cache rebuilds.

Build 17911 (25 Aug 2010)

  • Release Notes Build 17911, Auszug aus Enhancements and Bug Fixes:
    • Added support for greater then 2TB drive capacity.
    • Improved the DMA engine for configurations where the host system has greater then 4GB of memory.
    • Fixed an issue where a drive segment would report as Failed when the overall RAID status was Optimal.
    • Fixed a compatibility issue that would prevent Adaptec controllers from posting in Dell Tx10 servers.
    • Fixed a compatibility issue that would prevent Adaptec controllers from posting in HP ML110 servers.
    • Fixed an issue where drives would not be detected when installed on an HP backplane.
    • Fixed an issue where an array originally created using older controller firmware would not rebuild on a controller with newer firmware.
  • Adaptec Storage Manager v6.50.18579 Readme

Build 17899 (23 Apr 2010)

  • Release Notes Build 17899, Auszug aus Enhancements and Bug Fixes:
    • Improved the overall random read IOPS with multiple SSDs.
    • Upgraded the Java platform used by Adaptec Storage Manager to version 1.6.
    • Added MaxIQ support for Intel X25-E 64GB SSDs.
    • Added support for doing ATA Security Erase command for SATA drives from the ARCCONF utility.
    • Added functionality to display the SMART tags and their values within Adaptec Storage Manager.
    • Added new informational and statistical detail for SSD and MaxIQ monitoring within Adaptec Storage Manager and ARCconf, please see documentation.
    • Added a command line option to the ARCConf utility to save support files, similar to functionality already in Adaptec Storage Manager.
    • Fixed an issue where updating the ESX 4.0 driver would result in the system booting into recovery shell. You should now be able to update the driver when the Adaptec card is being used as the boot controller.
    • Fixed an issue where Western Digital WD2002FYPS drives would drop under heavy I/O on Adaptec High-Port controllers.
  • Adaptec Storage Manager v6.50.18570 Readme, Auszug:
    • FreeBSD 8.0 wird nun neben 6.4 und 7.2 auch unterstützt

Build 17544 (18 Nov 2009)

  • Release Notes Build 17544, Auszug aus Enhancements and Bug Fixes:
    • Added a new option in the “PHY Configuration” menu to change the Phy speed (3.0Gbps/1.5Gbps). Due to onboard expanders, this new option is not available on certain Series 5 controllers (51245, 51645, and 52245).
    • Fixed an issue where arrays may become unreadable after performing a firmware upgrade. Please refer to ASK knowledgebase article# 16914 for further detail.
    • Fixed an issue where the controller alarm would continue to sound, even after all drive members of the degraded array had been initialized.
    • Fixed an issue where a simple volume creation would fail if a secure erase was performed on the drive(s).
    • Fixed an issue that would prevent a hotspare from being pulled in and a rebuild from starting if an array became degraded as a result of an array drive member being initialized.
    • Enhancement to drive medium error handling. Drives exhibiting excessive medium errors will be marked offline.
    • Enhancement to array morphing and expansion should require less time to complete. This enhancement does not apply to array building or rebuilding.
    • Enhancement to the controller BIOS (CTRL-A), now displays the firmware build number at the top of the main menu screen.
  • Adaptec Storage Manager v6.40.18530 Readme

Build 17517 (9 Sep 2009)

Build 17380 (9 Jun 2009)

  • Release Notes Build 17380, Auszug aus Enhancements and Bug Fixes:
    • Support for the new Adaptec 5405z, 5445z, and the 5805z controllers
    • Support for VMware 4.0
    • Support for flashing drive firmware via Adaptec Storage Manager or ARCconf
    • Support for Intel Tylersburg Chipset based motherboards
    • Support for greater then 2TB physical drives
    • Support for additional SSD devices
    • Fixed an issue where in some cases a degraded RAID5 or RAID6 array would not rebuild
  • Adaptec Storage Manager v6.00.18451 Readme

Build 16501 (18 Feb 2009)

  • Release Notes Build 16501, Auszug aus Enhancements and Bug Fixes:
    • Increased RAID1 and RAID10 performance
    • Incorporated SLI Maintenance Release 3
    • Fixed an issue where in some cases a degraded RAID5 or RAID6 array would not rebuild
    • Fixed a PCIe link-training issue

Hinweis: nur die Firmware wurde in diesem Release aktualisiert, Treiber und ASM blieben unverändert

Build 16343 (8 Dec 2008)

  • Release Notes Build 16343, Auszug aus Enhancements and Bug Fixes:
    • Improved handling of Direct Access Storage Devices (i.e. Removable Drives)
    • Improved Power Management support in ARCCONF and Adaptec Storage Manager
    • Added option to the Ctrl+A utility to change cache settings for logical drives after their creation
  • Adaptec Storage Manager v6.10.18350 Readme

Hinweis: Adaptec hat die Downloadseite für ASM Version v6.10.18350 entfernt und durch v6.10.18359 ersetzt. Das Softwarepaket von v6.10.18350 enthielt eine alte README.TXT Datei.

Build 16116 (1 Aug 2008)

  • Release Notes Build 16116, Auszug aus Enhancements and Bug Fixes:
    • Added support for FreeBSD 6.3
    • Added support for SLES 10 SP2
    • Added Intelligent Power Management features to the controller firmware and ASM
    • Added Windows SCSIport driver
    • Added application aware performance tuning
    • Increased the number of drives to be used in a RAID5 to 32
    • Increased the number of logical drives supported to 64
    • Improved Medium Error Handling to all RAID levels
  • Adaptec Storage Manager v6.00.17922 Readme

Build 15738 (27 Apr 2008)

Release Notes Build 15738

Anmerkungen

  1. 1,0 1,1 1,2 1,3 erfordert zusätzlichen SAS Expander, z.B. durch Verwendung einer SAS Expander Backplane


Foto Werner Fischer.jpg

Autor: Werner Fischer

Werner Fischer arbeitet im Product Management Team von Thomas-Krenn. Er evaluiert dabei neueste Technologien und teilt sein Wissen in Fachartikeln, bei Konferenzen und im Thomas-Krenn Wiki. Bereits 2005 - ein Jahr nach seinem Abschluss des Studiums zu Computer- und Mediensicherheit an der FH Hagenberg - heuerte er beim bayerischen Server-Hersteller an. Als Öffi-Fan nutzt er gerne Bus & Bahn und genießt seinen morgendlichen Spaziergang ins Büro.


Das könnte Sie auch interessieren

Adaptec RAID Controller in VMware überwachen
Adaptec RAID Controller in VMware überwachen mit MaxView Storage Manager
Festplattenausfall bei Adaptec RAID Controller mit ARCCONF beheben